Prosthesis design and placement in reverse total shoulder arthroplasty

نویسندگان

  • David C Ackland
  • Minoo Patel
  • David Knox
چکیده

The management of irreparable rotator cuff tears associated with osteoarthritis of the glenohumeral joint has long been challenging. Reverse total shoulder arthroplasty (RSA) was designed to provide pain relief and improve shoulder function in patients with severe rotator cuff tear arthropathy. While this procedure has been known to reduce pain, improve strength and increase range of motion in shoulder elevation, scapular notching, rotation deficiency, early implant loosening and dislocation have attributed to complication rates as high as 62%. Patient selection, surgical approach and post-operative management are factors vital to successful outcome of RSA, with implant design and component positioning having a significant influence on the ability of the shoulder muscles to elevate, axially rotate and stabilise the humerus. Clinical and biomechanical studies have revealed that component design and placement affects the location of the joint centre of rotation and therefore the force-generating capacity of the muscles and overall joint mobility and stability. Furthermore, surgical technique has also been shown to have an important influence on clinical outcome of RSA, as it can affect intra-operative joint exposure as well as post-operative muscle function. This review discusses the behaviour of the shoulder after RSA and the influence of implant design, component positioning and surgical technique on post-operative joint function and clinical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reverse Total Shoulder Arthroplasty for the Treatment Of Synovial Chondromatosis: A Case Report and Review of the Literature

Synovial chondromatosis affecting the glenohumeral joint is rare. Treatment primarily consists of arthroscopic loose body removal and synovectomy. Shoulder arthroplasty has been mentioned in the literature as a treatment option for patients with coexisting arthritis, although the results have been underreported. The case of an 84-year-old man with long standing synovial chondromatosis of the sh...

متن کامل

Prosthetic design of reverse shoulder arthroplasty contributes to scapular notching and instability

AIM To evaluate whether implant design, glenoid positioning, and other factors influenced instability and scapular notching in reverse total shoulder arthroplasty. METHODS We retrospectively reviewed records of patients who had undergone reverse total shoulder arthroplasty by the senior author from July 2004 through October 2011 and who had at least 24 mo of follow-up. The 58 patients who met...

متن کامل

Avulsive axillary artery injury in reverse total shoulder arthroplasty.

In addition to neurologic injuries such as peripheral nerve palsy, axillary vessel injury should be recognized as a possible complication of reverse total shoulder arthroplasty. Limb lengthening associated with Grammont-type reverse total shoulder arthroplasty places tension across the brachial plexus and axillary vessels and may contribute to observed injuries. The Grammont-type reverse total ...

متن کامل

Reverse total shoulder arthroplasty: a review of results according to etiology.

BACKGROUND Reverse total shoulder arthroplasty provides a surgical alternative to standard total shoulder arthroplasty for the treatment of selected complex shoulder problems. The purpose of the present study was to evaluate the effects of etiology on the results of reverse total shoulder arthroplasty. METHODS Between May 1995 and June 2003, 240 consecutive reverse total shoulder arthroplasti...

متن کامل

Evolution of the reverse total shoulder prosthesis.

Over the last decade, reverse total shoulder arthroplasty has gained significant popularity due to its ability to address difficult reconstructive shoulder problems that could not be adequately treated in the past. The concept of the reverse shoulder prosthesis was introduced in the 1970s, but the initial attempts were associated with high complication and implant failure rates. The pioneering ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015