Analysis of hydrazine in smokeless tobacco products by gas chromatography–mass spectrometry

نویسندگان

  • Kevin McAdam
  • Harriet Kimpton
  • Sofia Essen
  • Peter Davis
  • Carl Vas
  • Christopher Wright
  • Andrew Porter
  • Brad Rodu
چکیده

BACKGROUND Due to the lower health risks associated with the use of certain categories of smokeless tobacco products (STPs) such as Swedish snus, there is interest in the comparative levels of toxic chemical constituents in different types of STPs. A method has been developed and validated for the analysis of hydrazine in STPs. Seventy four commercial STPs from the US and Sweden, representing 80-90% of the 2010 market share for all the major STP categories in these two countries, as well as three reference STPs, were analysed for hydrazine. RESULTS Aqueous extracts of the STPs were treated with excess pentafluorobenzaldehyde (PFB), which reacted with hydrazine in solution to form decafluorobenzaldehyde azine (DFBA). DFBA was partitioned into hexane and then quantified by gas chromatography-mass spectrometry (GC-MS). The method was validated using five different types of STP, was linear in the range 8-170 ng/mL, and had limits of quantification (LOQ) from 26-53 ng of hydrazine per g of STP (as sold). The method was applied to the analysis of 74 contemporary STPs commercially available in the United States and Sweden, none of which were found to contain hydrazine above the LOQ or LOD. Trace levels of compounds showing chromatographic and mass spectral features consistent with hydrazine were identified at very low levels (sub-limit of detection, <10 ng/g) in the chromatograms of less than half of the 74 STPs examined; in contrast, for 40 of the STPs no evidence for the presence of hydrazine was observed. Where present, the levels of compounds consistent with hydrazine were estimated to be at least an order of magnitude lower than the only previous study to have quantified hydrazine in tobacco. CONCLUSIONS Our results show that hydrazine is not a prevalent constituent of STPs, and when present is not quantifiable using currently available analytical methodology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Analytical Study on the Common Type of Smokeless Tobacco Available in the Iranian Market

BACKGROUND The use of smokeless tobacco is considered as a risk factor for oral cancer. OBJECTIVES The current study aimed to chemically analyze, separate and measure the existing substances in a type of chewing tobacco. MATERIALS AND METHODS In the current descriptive study, the investigated sample was a type of smokeless tobacco, known as BT, manufactured in India. First steam distillatio...

متن کامل

Perchloroethylene Analysis by Chemical Oxidation and Determination of Intermediate Products by Gas Chromatography, Mass Spectrometry

Abstract Background and Objective: Perchloroethylene (PCE) is a chlorinated hydrocarbon used as a solvent in many industrial processes. In contaminated water and soil a great deal of PCE is found. This study aimed to determine the rate of decomposition of PCE occurred after advanced oxidation. Material and Methods: In this descriptive-analytic study conducted (2011) in public health faculty...

متن کامل

Rapid and chemically selective nicotine quantification in smokeless tobacco products using GC-MS.

In recent years, there has been a rapid proliferation of smokeless products with a wide range of nicotine content and flavoring formulations that may appeal to new users and existing cigarette smokers. The CDC nicotine method, which employs gas chromatography-flame ionization detection (GC-FID), provides a robust means for measuring nicotine in smokeless tobacco. However, several compounds, ide...

متن کامل

Tobacco-specific nitrosamines and their pyridine-N-glucuronides in the urine of smokers and smokeless tobacco users.

Tobacco-specific nitrosamines are believed to play a significant role as causes of cancer in people who use tobacco products. Whereas the uptake of one tobacco-specific nitrosamine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, has been shown by analysis of its metabolites in urine, there are no published studies on urinary levels of N'-nitrosonornicotine (NNN), N'-nitrosoanatabine (NAT), and...

متن کامل

High-Intensity Sweeteners in Alternative Tobacco Products

INTRODUCTION Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -