Content and characterization of plasminogen activators in human lung tumors and normal lung tissue.

نویسندگان

  • G Markus
  • H Takita
  • S M Camiolo
  • J G Corasanti
  • J L Evers
  • G H Hobika
چکیده

The plasminogen activator content of surgically removed lung cancers, as well as that of adjacent normal lung tissue has been determined quantitatively. Optimum conditions for the quantitative extraction have been worked out using a modification of the technique described by Nagy et al. (Int. J. Cancer, 19:614-620, 1977) which utilizes a buffered solution of the non-ionic detergent Triton X-100. Plasminogen activator was significantly elevated in the tumors (2.5- to 4.3-fold over the normal lung, depending on sample selection and other criteria), although individual variations between tumors were extremely large. No significant correlation was found between the histopathological character of the tumors and the activator content, or between invasiveness and activator content. Using rabbit antibody formed against purified urokinase as an inhibitor of activator action, it was found that lung tumors contain a urokinase-like enzyme as the predominant plasminogen activator, while the activator content of the adjacent normal lung tissue consists of some urokinase-like enzyme, but mostly of an enzyme which is not inhibited by the antibody. The urokinase-like activator has been purified approximately 20,000-fold from lung tumors by the combination of two affinity chromatographic procedures, and was compared with purified urokinase with a molecular weight of 55,000 on all criteria used, the lung tumor activator was identical to urokinase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy

Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose.  In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...

متن کامل

Immunological analysis of plasminogen activators from normal and transformed hamster cells. Evidence that the plasminogen activators produced by SV40 virus-transformed hamster embryo cells and normal hamster lung cells are antigenically identical

Rabbits were immunized against the plasminogen activator released by SV4- virus-transformed hamster embryo cells. The resulting antiplasminogen activator immunoglobulin (APA-IgG) inhibited the enzymatic activity of the plasminogen activator produced by SV40-transformed hamster cells, and the plasmin-catalyzed release of these cells from the tissue culture dish. APA-IgG was not cytotoxic for t...

متن کامل

Increase of urokinase-type plasminogen activator gene expression in human lung and breast carcinomas.

To assess the postulated correlation between plasminogen activators (PAs) and malignancy, we determined the mRNA content for urokinase-type (u-PA) and tissue-type (t-PA) enzymes in a prospective series of 29 primary lung and 27 primary breast carcinomas. Dot blots of total RNAs were hybridized with appropriate cRNA probes under conditions that allow quantitative measurement of the mRNA level fo...

متن کامل

Evaluation of the dose and flux of secondary particles in the lung tissue in breast proton therapy using the Monte Carlo simulation code

Unlike proton therapy, conventional radiation therapy directs X-rays not only at the tumor but also unavoidably at nearby healthy tissue. Protons deliver radiation to tumor tissue while the healthy structures will be spared during proton therapy. When protons travel through matter, secondary particles like neutrons and photons are produced. It is believed that the secondary dose can lead to sec...

متن کامل

بررسی دز رسیده به بافت‌ سالم ریه در پرتودرمانی تومورهای ریوی به دو روش پرتودرمانی گیتد و معمولی

In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the CTV. With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), using the NCAT digital phantom. Different series of CT im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer research

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 1980