Refrigerant Retrofit in Sweden - Field and Laboratory Studies

نویسندگان

  • L. Herbe
  • P. Lundqvist
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory Evaluation and Field Tests of Replacements for R22 and R502

Per Lundqvist Dr., Lars Herbe M.Sc, The Royal Institute ofTechnology, Dept. of Energy Technology, S-100 44, Stockholm, Sweden Fax: +46 8 20 30 07 Tel: +46 8 790 74 52 Email: [email protected] There are several important issues when dealing with new refrigerants in a retrofit situation. This paper is however restricted to system performance and a discussion of methods suitable to determine ...

متن کامل

Replacement of R22 in Existing Installations: Experiences from the Swedish Phase Out

The phase out of R22 as working media in refrigerating machines and heat pumps in Sweden began in 1998 with a stop for new installations. From January 1st 2002 a refill stop takes effect. A project called Replacement of R22 in new and existing facilities – energy efficiency, economy and environmental consequences within the Swedish Energy Administrations research programme Climate 21 (Klimat 21...

متن کامل

Optimal Distribution of Condenser Area for Retrofits

A. 1 ohansson and P. Lundqvist Dept. of Energy Technology Div. of Applied Thennodynamics and Refrigeration The Royal Institute of Technology, KTH Stockholm, Sweden Test results from field retrofit situations, where R22 has been changed to Isceon 59 1 and R407C in two identical chillers, shows that both substitutes require more subcooling than R22 to give the system a satisfying performance. It ...

متن کامل

Effectiveness of Energy Retrofit on Energy Consumption and Occupants' Comfort: Case of Shahid Beheshti University Dorimitories

In addition to the building properties effect on energy consumption, it is important to consider occupant’s energy behavior and their interaction with building systems in energy calculations. According to studies, energy retrofit regardless of considering this factor, has a lower effect on reducing the energy consumption. This study investigates the impact of energy retrofit in two (retrofitted...

متن کامل

Near Azeotrope Refrigerants to Replace R502 in Commercial Refrigeration

The Refrigerant RS02, an azeotrope of CFCllS and HCFC22, is an important refrigerant in commercial refrigeration, especially for low temperature applications using single stage compressors. current users of R502 are faced with an earlier than ~nticipated phase-out and are under great pressure to find suitable alternates for retrofit and o.E.M. (new) applications. Single components like HCFC12S,...

متن کامل