Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use

نویسندگان

  • Laurent Muller
  • Xavier Bobbia
  • Mehdi Toumi
  • Guillaume Louart
  • Nicolas Molinari
  • Benoit Ragonnet
  • Hervé Quintard
  • Marc Leone
  • Lana Zoric
  • Jean Yves Lefrant
چکیده

INTRODUCTION To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF). METHODS Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge was defined as a 15% increase of subaortic velocity time index (VTI) measured by transthoracic echocardiography. Inferior vena cava diameters were recorded by a subcostal view using M Mode. The cIVC was calculated as follows: (Dmax - Dmin/Dmax) × 100 and then receiver operating characteristic (ROC) curves were generated for cIVC, baseline VTI, E wave velocity, E/A and E/Ea ratios. RESULTS Among 40 included patients, 20 (50%) were responders (R). The causes of ACF were sepsis (n = 24), haemorrhage (n = 11), and dehydration (n = 5). The area under the ROC curve for cIVC was 0.77 (95% CI: 0.60-0.88). The best cutoff value was 40% (Se = 70%, Sp = 80%). The AUC of the ROC curves for baseline E wave velocity, VTI, E/A ratio, E/Ea ratio were 0.83 (95% CI: 0.68-0.93), 0.78 (95% CI: 0.61-0.88), 0.76 (95% CI: 0.59-0.89), 0.58 (95% CI: 0.41-0.75), respectively. The differences between AUC the ROC curves for cIVC and baseline E wave velocity, baseline VTI, baseline E/A ratio, and baseline E/Ea ratio were not statistically different (p = 0.46, p = 0.99, p = 1.00, p = 0.26, respectively). CONCLUSION In spontaneously breathing patients with ACF, high cIVC values (>40%) are usually associated with fluid responsiveness while low values (< 40%) do not exclude fluid responsiveness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory variation in inferior vena cava diameter: surrogate of central venous pressure or parameter of fluid responsiveness? Let the physiology reply

In the previous issue of Critical Care, Muller and colleagues investigated whether respiratory variation in inferior vena cava diameter (ΔIVC) could be a useful predictor of fluid responsiveness in spontaneously breathing patients. The study concludes that accuracy was not very good and therefore that this parameter should be used with caution in these patients. There is still confusion about t...

متن کامل

Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?

INTRODUCTION We have almost no information concerning the value of inferior vena cava (IVC) respiratory variations in spontaneously breathing ICU patients (SBP) to predict fluid responsiveness. METHODS SBP with clinical fluid need were included prospectively in the study. Echocardiography and Doppler ultrasound were used to record the aortic velocity-time integral (VTI), stroke volume (SV), c...

متن کامل

The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation

Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...

متن کامل

Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically-ill patients.

PURPOSE Measurement of inferior vena cava collapsibility (cIVC) by point-of-care ultrasound (POCUS) has been proposed as a viable, non-invasive means of assessing fluid responsiveness. We aimed to determine the ability of cIVC to identify patients who will respond to additional intravenous fluid (IVF) administration among spontaneously breathing critically-ill patients. METHODS Prospective ob...

متن کامل

Identification of congestive heart failure via respiratory variation of inferior vena cava diameter.

INTRODUCTION Rapid diagnosis of volume overload in patients with suspected congestive heart failure (CHF) is necessary for the timely administration of therapeutic agents. We sought to use the measurement of respiratory variation of inferior vena cava (IVC) diameter as a diagnostic tool for identification of CHF in patients presenting with acute dyspnea. METHODS The IVC was measured sonograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2012