Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
نویسندگان
چکیده
Helical Tomotherapy (HT) has become increasingly popular over the past few years. However, its clinical efficacy and effectiveness continues to be investigated. Pre-treatment patient repositioning in highly conformal image-guided radiation therapy modalities is a prerequisite for reducing setup uncertainties. A MVCT image set has to be acquired to account for daily changes in the patient's internal anatomy and setup position. Furthermore, a comparison should be performed to the kVCT study used for dosimetric planning, by a registration process which results in repositioning the patient according to specific transitional and rotational shifts. Different image registration techniques may lead to different repositioning of the patient and, as a result, to varying delivered doses. This study aims to investigate the expected effect of patient setup correction using the Hi-Art tomotherapy system by employing radiobiological measures such as the biologically effective uniform dose (BEUD) and the complication-free tumor control probability (P+). In this study, a typical case of lung cancer with metastatic head & neck disease was investigated by developing a Helical Tomotherapy plan. For the Tomotherapy HiArt plan, the dedicated Tomotherapy treatment planning station was used. Three dose distributions (planned and delivered with and without patient setup correction) were compared based on radiobiological measures by using the P+ index and the BEUD concept as the common prescription point of the plans and plotting the tissue response probabilities against the mean target dose for a range of prescription doses. The applied plan evaluation method shows that in this cancer case the planned and delivered dose distributions with and without patient setup correction give a P+ of 81.6%, 80.9% and 72.2%, for a BEUD to the planning target volume (PTV) of 78.0Gy, 77.7Gy and 75.4Gy, respectively. The corresponding tumor control probabilities are 86.3%, 85.1% and 75.1%, whereas the total complication probabilities are 4.64%, 4.20% and 2.89%, respectively. HT can encompass the often large PTV required while minimizing the volume of the organs at risk receiving high dose. However, the effectiveness of a HT treatment plan can be considerably deteriorated if an accurate patient setup system is not available. Taking into account the dose-response relations of the irradiated tumors and normal tissues, a radiobiological treatment plan evaluation can be performed, which may provide a closer association of the delivered treatment with the clinical outcome. In such situations, for effective evaluation and comparison of different treatment plans, traditional dose based evaluation tools can be complemented by the use of P+,BEUD diagrams.
منابع مشابه
Initial clinical experience with helical tomotherapy for head and neck cancer.
BACKGROUND To report a single-institutional experience with the use of helical tomotherapy (HT)-based intensity-modulated radiotherapy (IMRT) for head and neck cancer. METHODS Seventy-seven consecutive patients were treated with HT for squamous cell carcinoma of the head and neck to a median dose of 66 Gy (range, 60 to 72 Gy). Megavoltage CT scans were obtained as part of an image-guided regi...
متن کاملAnalysis of peripheral doses for base of tongue treatment by linear accelerator and helical TomoTherapy IMRT
The purpose of this study was to compare the peripheral doses to various organs from a typical head and neck intensity-modulated radiation therapy (IMRT) treatment delivered by linear accelerator (linac) and helical TomoTherapy. Multiple human CT data sets were used to segment critical structures and organs at risk, fused and adjusted to an anthropomorphic phantom. Eighteen contours were design...
متن کاملOptimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study
Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...
متن کاملMegavoltage CT images of helical tomotherapy unit for radiation treatment simulation: impact on feasibility of treatment planning in a prostate cancer patient with bilateral femoral prostheses.
Metal prosthesis artefacts on CT images can be a significant problem in the definition of volumes of interest, dose calculation and patient setup in modern radiotherapy. We experienced considerable difficulties in defining the organs at risk and treatment volumes on kVCT images of standard CT simulation in a prostate cancer patient due to the presence of bilateral femoral prostheses causing art...
متن کاملEvaluation of MVCT imaging dose levels during helical IGRT: comparison between ion chamber, TLD, and EBT3 films
The purpose of this investigation was to evaluate the dose on megavoltage CT (MVCT) images required for tomotherapy. As imaging possibilities are often used before each treatment and usually used several times before the session, we tried to evaluate the dose delivered during the procedure. For each scanning mode (fine, normal, and coarse), we first established the relative variation of these d...
متن کامل