Detergent-containing glucose oxidase reagent for use with the Beckman glucose analyzer.
نویسندگان
چکیده
We describe a modified glucose oxidase reagent for use in the polarographic determination of glucose with the Beckman "Glucose Analyzer." The reagent contains 1 mL/L of a surfactant (Brij-35 250 g/L solution) as the wetting agent instead of glycerol. Precipitation of components associated with the formulation recommended by Fischl et al. [Clin. Chem. 21, 760 (1975)] does not occur with this reagent. It can be used immediately after preparation. When compared to analytical performance of the commercially prepared reagent, the precision was unchanged by the modified reagent, but the upper limit of accurate response was diminished (7.5 g/L vs. 6.7 g/L). The modified reagent is less expensive than are commercially prepared reagents.
منابع مشابه
Preparation of a modified glucose oxidase reagent for the polarographic determinationof glucose with the Beckman "glucose analyzer".
In this modification, glucose oxidase, 140-180 U/ml, is dissolved in acetate buffer (pH 6):ethanol (96%):glycerol (80:10:10 by vol). Iodine and molybdate are used as catalysts, formaldehyde and mercuric iodide as preservatives, and octanol as an antifoaming agent. The reagent is suitable for use in the Beckman "Glucose Analyzer", it is stable at room temperature for at least six months, it is s...
متن کاملEvaluation of Trinder's glucose oxidase method for measuring glucose in serum and urine.
Trinder's method for glucose has nearly all the attributes of an ideal automated colorimetric glucose oxidase procedure. The chemicals used in the color reaction with peroxidase are readily available, the solutions are stable and can be prepared by the user, the method is highly specific and largely free of interferences, the sensitivity can be adjusted by the user to cover a wide range of gluc...
متن کاملPlasma glucose measurement with the Yellow Springs Glucose Analyzer.
The Yellow Springs Glucose Analyzer, a device for the quantitative measurement of glucose concentrations, involves the use of immobilized glucose oxidase, incorporated on a membrane covering a hydrogen peroxide sensor. Operation of the instrument is simple. After an initial calibration, 25 microliter of plasma is injected into a reaction chamber. At 45 s a digital result for glucose is displaye...
متن کاملEvaluation of the co-immobilized hexokinase/glucose-6-phosphate dehydrogenase method for glucose, as adapted to the Technicon SMAC.
We assessed the analytical performance of the co-immobilized hexokinase (EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) method for D-glucose analysis on the Technicon SMAC. The enzyme-containing coils were usable for one month, or 12 000 tests. Bilirubin, hemoglobin, lipemia, creatinine, uric acid, citric acid, and ascorbic acid did not interfere. Results with this method were ...
متن کاملThe "eyetone" blood glucose reflectance colorimeter evaluated for in vitro and in vivo accuracy and clinical efficacy.
We evaluated the performance of a blood glucose reflectance colorimeter ("Eyetone," Ames Co.) for accuracy and precision with use of "Dextrostix" (Ames Co.) glucose oxidase reagent strips for blood samples with known and unknown concentrations of glucose covering the usual range of neonatal blood glucose (200-800 mg/L). The meter was calibrated and tested by research nurses and one clinical che...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 1 شماره
صفحات -
تاریخ انتشار 1979