Future template numerical interpretation techniques for PD pulse location in transformer windings

نویسنده

  • Jeyabalan Velandy
چکیده

Identification and location of partial discharge (PD) source is an important diagnostic tool for reliable operation of transformer. In this paper, future template numerical interpretation techniques are proposed for location of PD pulse duration from 0.1 s to 5 s in transformer windings using sweep frequency response analysis (SFRA) principle. To analyze the efficacy of the proposed techniques due to different PD pulses, experimental studies are performed on 22 kV transformer windings by injecting a voltage source of PD pulse across each winding section (tapping). According to Parseval’s theorem, energy distributions of the winding responses are calculated to decide on time period/frequency range to be considered for analysis. The measured winding responses obtained due to injection of 1 s reference pulse across the winding are considered as reference responses. If the PD has occurred any where within the winding, numerical interpretation coefficient has to observe real PD response and make a ‘best estimate/best matches’ with reference responses through appropriate mathematical formulation. The best matches will give the originating source of PD. To predict the confidence limits and significances of numerical interpretation coefficients output for PD pulse location, hypothesis test and probable error methods are utilized. © 2014 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion

Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...

متن کامل

Mathematical Proof for the Minimized Stray Fields in Transformers Using Auxiliary Windings Based on State Equations for Evaluation of FEM Results

Stray magnetic field is one of the main issues in design of transformers, since it causes non-ideal behavior of transformers. One of the techniques is usually adopted to mitigate the unwanted stray magnetic field is the use of auxiliary windings creating a magnetic field opposite to the incident one giving rise to the reduction of the total magnetic fields. This paper presents a new mathematica...

متن کامل

Investigation of Partial Discharge Propagation and Location in Multiple-α and Single- Α Transformer Windings Using Optimized Wavelet Analysis

Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and...

متن کامل

A Signal Processing Technique for PD Detection and Localization in Power Transformer Winding

Precise detection and localization of faults in power transformer windings for ultimate protection is the key issue. The insulation quality in windings majorly determines the enduring transformers function. Achieving as accurate and efficient detection method of partial discharge (PD) in transformer windings is challenging. The occurrence of PD being primarily responsible for the transformers f...

متن کامل

مدلسازی سیم پیچ ترانسفورماتورهای قدرت با استفاده از مدل خط انتقال چند سیمه بمنظور مکانیابی تخلیه جزئی

In this paper Multi conductor transmission line model (MTLM) was used for partial discharge (PD) localization in power transformers’ windings. The parameters of the model were computed considering practical issues of power transformer design. To decrease computational complexity of the model, two methods for calculation of model parameters were studied and the most suitable method was cho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016