A Preliminary Study on Spatial Sampling for Topographic Data
نویسندگان
چکیده
In this paper, an effective spatial sampling method is preliminary explored to assess the quality of the topographic data. The most novel idea in this study is we think the error as noise in the signal and we hope to direct spatial sampling through realizing this idea. First, we perform a prior partition of the original topographic data on the basis of the different error levels after a rough classification. Second, errors are supposed to obey the normal distribution, so we can use different Gaussian filters to remove the errors in each region. Then error-free topographic data after filtering can be seen as the true data. Finally, on the basis of this result, we can obtain the difference between the original topographic data and the error-free topographic data and then configure an error surface. The extreme points on the error surface are seen as the representative of the sampling sets. Finding the extreme points on the error surface is equivalent to selecting the least amount of sample points; meanwhile, these sample points can reflect the true error of the topographic data. By means of the proposed method, we hope to find the most optimum selection of spatial sample points from feature points, which can depict an approximate distribution of the errors, as well as reflect the entire quality of the topographic map.
منابع مشابه
Preliminary Studies on Contour Tree-based Topographic Data Mining
After many years of intensive investigation and mapping of the topography, a large number of topographic maps were produced by national mapping agencies. The explosive growth and wide availability of topographic data has created a data-rich environment for a variety of GIS users. How to make the best use of such topographic data has become a basic but daunting task. The research challenge now i...
متن کاملTheir Relationship to Topographic Indices
Understanding variability patterns in soil moisture is critical for determining an optimal sampling scheme both in space and in time, as well as for determining optimal management zones for agricultural applications that involve moisture status. In this study, distributed near-surface gravimetric soil moisture samples were collected across a 3.3 ha field in central Illinois for ten dates in the...
متن کاملCovariance of Biophysical Data With Digital Topographic and Land Use Maps Over the FIFE Site
Sampling design is critical in locating ground sampling stations for large-scale climatological field experiments. In the stratified sampling design adopted for the First International Satellite Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE), the study region was stratified into 14 different terrain units based on land use/land cover and topographic variables that were hypoth...
متن کاملPreliminary Site Selection of Pumped Storage Hydropower Plants - A GIS-based approach
The first stage in development and design of Pumped Storage Hydropower Plants (PSHP) is finding the optimum location. This paper presents a methodology for preliminary site selection of PSHP with the help of geospatial data analysis in a Geographic Information System (GIS) environment. The conventional method of PSHP site selection has certain limitations and is not cost and time effective. The...
متن کاملQuantifying Uncertainty of Digital Elevation Models Derived from Topographic Maps
This paper explores a methodology for quantifying the uncertainty of DEMs created by digitising topographic maps. The origins of uncertainty in DEM production were identified and examined. The uncertainty of DEM data was quantified by computing a vector total of Root Mean Square Error (RMSE) from the source map, sampling and measurement errors, and the interpolation process. Distributional meas...
متن کامل