Effects of ampholyte dissociation constants on protein separation in on-chip isoelectric focusing.
نویسندگان
چکیده
Numerical simulations are presented for ampholyte-based isoelectric focusing in 2D microgeometries. In this study, model proteins are focused in the presence of 25 biprotic ampholytes under an applied electric field. Each protein is considered as a simple polypeptide having ten charge states, while the biprotic ampholytes are selected to generate a shallow pH range of 6 to 9. Straight and contraction-expansion microchannels are considered here, and a nominal electric field of 300 V/cm is maintained for separation of proteins. Six distinct values of deltapKs between 1 and 3.5 are investigated for ampholytes to form pH profiles in a 1 cm long microchannel. Simulation results show that relatively larger values of deltapK(deltapK > 3) are required to form stepless pH profiles in the system. The peak heights and differential resolutions of focused proteins are much higher for lower values of deltapK for which a stepped pH profile is evident. For each protein, the time it takes for the two edges of a peak to merge increases linearly with deltapK, while the focusing time goes up exponentially with increasing deltapK. Both merging and focusing times of protein are higher for contraction-expansion microchannel than those of straight microchannel. For a particular value of deltapK, the contracted "Zoom" region of contraction-expansion channel is able to form more tightly focused bands than the expanded region.
منابع مشابه
Effects of ampholyte concentration on protein behavior in on-chip isoelectric focusing.
The effects of mobility corrections on carrier ampholytes are studied at various ampholyte concentrations to understand protein behavior during IEF. IEF simulations are conducted in the presence of 25 biprotic carrier ampholytes within a pH range of 6-9 after applying the Onsager-Debye-Hückel correction to the carrier ampholytes. Two model proteins with ten charge states but without ionic stren...
متن کاملMicrofluidic 2-D PAGE using multifunctional in situ polyacrylamide gels and discontinuous buffers.
A two-dimensional microfluidic system is presented for intact protein separations combining isoelectric focusing (IEF) and sodium dodecyl sulfate (SDS) polyacrylamide gel electrophoresis (PAGE) employing in situ photopolymerized polyacrylamide (PAAm) gels. The PAAm gels are used for multiple functions. In addition to serving as a highly-resolving separation medium for gel electrophoresis, discr...
متن کاملEffects of separation length and voltage on isoelectric focusing in a plastic microfluidic device.
This paper describes the investigation on the effects of separation length and voltage on IEF in a plastic microfluidic device. A LIF, whole-channel imaging detection (WCID) system was developed to monitor proteins while they were moving under an electric field. IEF was carried out in a separation medium consisting of carrier ampholytes and a mixture of linear polymers (hydroxyethylcellulose an...
متن کاملDevelopment of non-gel-based two-dimensional separation of intact proteins by an on-line hyphenation of capillary isoelectric focusing and hollow fiber flow field-flow fractionation.
A rapid, non-gel-based, on-line, two-dimensional separation method is introduced for proteome analysis. Protein fractionation was carried out by first exploiting the differences in their respective isoelectric points (pI) in a Teflon capillary using isoelectric focusing (IEF), followed by a molecular weight (MW)-based separation in a hollow fiber by flow field-flow fractionation (FlFFF). The me...
متن کاملOn-chip coupling of isoelectric focusing and free solution electrophoresis for multidimensional separations.
We have developed an acrylic microfluidic device that sequentially couples liquid-phase isoelectric focusing (IEF) and free solution capillary electrophoresis (CE). Rapid separation (<1 min) and preconcentration (73x) of species were achieved in the initial IEF dimension. Using full-field fluorescence imaging, we observed nondispersive mobilization velocities on the order of 20 microm/s during ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nanoscience and nanotechnology
دوره 8 7 شماره
صفحات -
تاریخ انتشار 2008