Coronary Aneurysm Formation after Titanium Nitric Oxide-Coated Stent Implantation
نویسندگان
چکیده
Coronary artery aneurysm (CAA) formation is a rare complication after percutaneous coronary intervention (PCI) with stent implantation. Why CAA occurs in these unusual instances is not well understood. Though cases with drug-eluting stent (DES) induced CAA have been reported before, none was reported to be associated with a titanium nitric oxide-coated bioactive stent. Herein, we describe the first case where CAA developed after titanium nitric oxide-coated bioactive stent implantation. Several mechanisms may account for stent-related CAA formation, including mechanical trauma, vessel remodeling, acute myocardial infarction, long or multiple DES stent implantation, DES malapposition and hypersensitivity reaction to polymers. A 53-year-old man presented initially with recent MI and ongoing chest pains. Coronary angiography revealed a 90% occlusion of the middle left anterior descending coronary artery (LAD). PCI was performed on the patient, and a titanium nitric oxide-coated bioactive stent was implanted. Due to a positive thallium scan 28 months later, a follow-up coronary angiography scan revealed a true CAA, which was then further confirmed by intravascular ultrasound. Thereafter, the patient remained asymptomatic at subsequent follow-ups, and continued medical treatment without further intervention. Herein, we discuss the possible etiologies, mechanisms and further treatments of CAA formation after titanium nitric oxide-coated bioactive stent implantation.
منابع مشابه
Management of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction
Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent
متن کامل[Coronary artery aneurysm one year and five months after sirolimus-eluting stent placement].
A 52-year-old man with diagnosis of post-infarction unstable angina. Coronary angiography revealed 90% luminal obstruction in the middle third of the right coronary artery and 90% in the marginal branch of the circumflex artery. After the administration of clopidogrel 300 mg associated with acetylsalicylic acid, the patient underwent the implantation of a sirolimus-eluting stent (CYPHER; Johnso...
متن کاملNitric-oxide coated bioactive titanium stents: safer and more effective than second-generation drug-eluting stents?
Polymer-coated drug-eluting stents (DESs) have become the treatment of choice in most patients undergoing percutaneous coronary interventions. Although these stents are effective in the sense that they reduce the restenosis rate and the need for repeat intervention by 70% compared with bare-metal stents, concerns have been raised about a series of risks closely related to the metal mesh of the ...
متن کاملTwo-year follow-up after percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus paclitaxel-eluting stents in acute myocardial infarction.
BACKGROUND AND AIMS The aim of this study was to evaluate the long-term effects of the titanium-nitride-oxide-coated (TITANOX) stent and the paclitaxel-eluting stent (PES) in patients who had undergone a percutaneous coronary intervention for acute myocardial infarction (MI). METHODS AND RESULTS The TITAX-AMI trial randomly assigned 425 patients with MI to receive either a TITANOX stent or a ...
متن کاملA cockscomb-like aneurysm of the right coronary artery after bare metal stent implantation
Coronary artery aneurysm (CAA) formation is an uncommon but potentially life-threatening event after coronary balloon angioplasty or stent implantation. In this report, we present a case of a patient who had a cockscomb-like aneurysm after bare metal stent implantation which was successfully treated with a coronary graft stent.
متن کامل