SU-E-T-593: VMAT Vs. IMRT for Treatment of Neoplasms of the Brain: Dosimetric Quality and Delivery.

نویسندگان

  • G Gilson
  • S Perkins
  • F Xia
  • C Coffey
  • G Ding
چکیده

PURPOSE A retrospective study was performed to determine any dosimetric or delivery benefits for treatment planning with intensity-modulated radiotherapy (IMRT) versus volumetric-modulated arc therapy (VMAT) for the treatment of brain neoplasms. METHODS Eighteen patients treated with modulated brain radiotherapy treatments were included in this study (primary treatment volumes of 15.3 to 374.9 cc). IMRT and VMAT plans were generated for each patient using the same criteria for prescription coverage and normal tissue sparing. IMRT optimizations ranged from five to seven fields and VMAT from two to four arcs. Plans were generated with Varian Eclipse treatment planning system utilizing AAA-8615 dose calculation algorithm. RESULTS VMAT optimizations provided limited dosimetric advantages versus IMRT. VMAT provided superior treatment volume coverage (volumes receiving 95%, 100% of prescription dose (V95%, V100%)) over IMRT, but differences were not statistically significant (paired t-test p > 0.05). Relative maximum dose values, conformity and homogeneity indices also exhibited no statistical differences. IMRT plans resulted in similar mean brain minus treatment volume (Brain- TV) dose (mean = 1460.1 vs. 1506.3 cGy; p = 0.056). The volume of Brain- TV receiving 40Gy was lower for VMAT than IMRT (average = 38.96 vs. 44.97 cc; p = 0.050). Maximum skin dose was lower for VMAT (mean = 4568.8 vs. 5063.3cGy; p = 0.006), as well as skin V20Gy (6.56% vs 7.69%; p = 0.027) and V40Gy (0.56% vs. 0.35%; p = 0.017). VMAT plans required fewer fields along with fewer MU than IMRT (mean = 388.2 vs. 721.1 MU, respectively), allowing for approximately 20% faster delivery times. CONCLUSIONS VMAT treatments significantly reduced treatment time due to reduced MU and fewer fields. Certain skin and Brain-TV high dose spread parameters were superior for VMAT as compared to IMRT plans. All other dosimetric parameters tested were statistically equivalent for VMAT and IMRT techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Dosimetric advantage of volumetric modulated arc therapy in the treatment of intraocular cancer

OBJECTIVE The purpose of this study is to investigate the dosimetric advantages of volumetric modulated arc therapy (VMAT) in the treatment of intraocular cancer by comparing it directly with three-dimensional conformal radiotherapy (CRT) and intensity-modulated radiotherapy (IMRT). METHODS CRT plan, 7f-IMRT plan, and one-arc VMAT plan were generated for 14 intraocular cancer patients. Dosime...

متن کامل

SU-E-T-584: Dosimetric Comparison Between Static IMRT and VMAT for a Four- Lesion Brain Treatment.

PURPOSE Sparing brain volume is the goal when designing plans for multiple brain tumors. We compared dose distributions for tumor and normal tissues using VAMT and static IMRT. METHODS A patient presented with recurrent meningioma with 4 lesions identified. The greatest dimensions for the tumors were 0.4 to 2.0 cm. The tumor sizes and locations can be treated with a single plan with 1.8 Gy/fr...

متن کامل

A Hybrid IMRT/VMAT Technique for the Treatment of Nasopharyngeal Cancer

Hybrid IMRT/VMAT technique which combined intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) was developed for the treatment of nasopharyngeal cancer (NPC). Two-full-arc VMAT (2ARC-VMAT), 9-field IMRT (9F-IMRT), and Hybrid IMRT/VMAT plans for NPC were compared in terms of the dosimetric quality, sparing of organs at risk (OARs), and delivery efficiency. The Hybr...

متن کامل

A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

BACKGROUND To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part19  شماره 

صفحات  -