Non-destructive assessment of cavity wall adaptation of class V composite restoration using swept-source optical coherence tomography.

نویسندگان

  • Pisol Senawongse
  • Pong Pongprueksa
  • Choltacha Harnirattisai
  • Yasunori Sumi
  • Masayuki Otsuki
  • Yasushi Shimada
  • Junji Tagami
چکیده

The purpose of this study was to evaluate gap formations under class V restoration using swept-source optical coherence tomography (SS-OCT). Wedge-shaped cavities were prepared on the buccal surface of 40 extracted premolar teeth at 2 locations; 1) cemento-enamel junction (CEJ) with enamel and cementum margin and 2) root surfaces with cementum margin. The cavity was treated with Clearfil S(3) Bond, restored with Clearfil Majesty and polished with abrasive disks. The specimens were kept in water at 37°C for 24 hours and subjected to a thermocycling procedure. Gap formations at the tooth-restoration interface were measured with SS-OCT image and conventional dye leakage under a microscope. There was no effect of the locations of the cavity and the margins of the cavity on the gap formation. Therefore, a significant effect of the observational methods was observed. The gap formation was 0.89±0.48 mm with the SS-OCT, and the gap formation was 0.34±0.41 mm with the dye leakage. The observation with SS-OCT demonstrated a greater degree of gap formation than the observation with dye leakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D evaluation of composite resin restoration at practical training using swept-source optical coherence tomography (SS-OCT).

Internal adaptation of restorations to the cavity wall is one of the important topics in clinical dentistry. The purpose of this study was to investigate the possibility to utilize the non-invasive tomographic imaging system for teaching the importance of cavity adaptation at dental school pre-clinical training. Swept-source optical coherence tomography (SS-OCT) was used for detection of margin...

متن کامل

Nondestructive assessment of current one-step self-etch dental adhesives using optical coherence tomography.

ABSTRACT. This study aimed to nondestructively evaluate sealing performance of eight one-step self-etch adhesives (1-SEAs) using optical coherence tomography (OCT). The two-step self-etch adhesive (2-SEA) served as the control. Round tapered class-I cavities (D=4 mm, H=2 mm) were prepared in bovine incisors, treated with each adhesive (n=5), and restored with a flowable resin composite. Cross-s...

متن کامل

Optical Coherence Tomography Combined with the Confocal Microscopy Method and Fluorescence for Class V Cavities Investigations

The purpose of this study is to present a non invasive method for the marginal adaptation evaluation in class V composite restorations. Standardized class V cavities, prepared in human extracted teeth, were filled with Premise (Kerr) composite. The specimens were thermo cycled. The interfaces were examined by Optical Coherence Tomography method (OCT) combined with the confocal microscopy and fl...

متن کامل

High-speed, high-resolution optical coherence tomography retinal imaging with a frequency-swept laser at 850 nm.

High-speed, high-resolution optical coherence tomography (OCT) imaging of the human retina is demonstrated using a frequency-swept laser at 850 nm. A compact external cavity semiconductor laser design, optimized for swept-source ophthalmic OCT, is described. The laser enables an effective 16 kHz sweep rate with >10 mm coherence length and a tuning range of approximately 35 nm full width at half...

متن کامل

High-precision, high-accuracy ultralong-range swept-source optical coherence tomography using vertical cavity surface emitting laser light source.

We demonstrate ultralong-range swept-source optical coherence tomography (OCT) imaging using vertical cavity surface emitting laser technology. The ability to adjust laser parameters and high-speed acquisition enables imaging ranges from a few centimeters up to meters using the same instrument. We discuss the challenges of long-range OCT imaging. In vivo human-eye imaging and optical component ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental materials journal

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2011