Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study
نویسندگان
چکیده
OBJECTIVES The objective of this study is to mathematically evaluate the influence of multiple factors on implant stability quotient values in clinical practice. PATIENTS AND METHODS Resonance frequency analysis was performed at T1 (measured immediately at the time of implant placement) and at T2 (measured before dental restoration) in 177 patients (329 implants). Using a multivariate linear regression model, we analyzed the influence of the following eleven candidate factors: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting (presence or absence), insertion torque, I-/II-stage healing pattern, implant diameter, implant length, and T1-T2 time interval. RESULTS The following factors were identified to significantly influence the implant stability quotient (ISQ) values at T1: insertion torque, bone grafting, I-/II-stage healing pattern, immediate/delayed implantation, maxillary/mandibular location, implant diameter, and sex. In contrast, the ISQ values at T2 were significantly influenced only by three factors: implant diameter, T1-T2 time interval, and insertion torque. CONCLUSION Among the eleven candidate factors, seven key factors were found to influence the T1-ISQ values, while only three key factors influenced the T2-ISQ values. Both T1 and T2-ISQ values were found to be influenced by implant diameter and insertion torque. T1 was influenced specifically by the sex of the patient, the location (maxillary or mandibular), the implantation mode (immediate/delayed implantation), the healing stage, and the absence or presence of bone graft materials.
منابع مشابه
Multivariate linear regression analysis to identify general factors for quantitative predictions of implant stability quotient values
OBJECTIVES This study identified potential general influencing factors for a mathematical prediction of implant stability quotient (ISQ) values in clinical practice. METHODS We collected the ISQ values of 557 implants from 2 different brands (SICace and Osstem) placed by 2 surgeons in 336 patients. Surgeon 1 placed 329 SICace implants, and surgeon 2 placed 113 SICace implants and 115 Osstem i...
متن کاملRisk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study
Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...
متن کاملClinical evaluation of the stability of implants placed at different supracrestal levels
PURPOSE The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. MATERIALS AND METHODS This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group), ...
متن کاملComparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts
Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...
متن کاملBiomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis
BACKGROUND This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). MATERIAL AND METHODS Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remain...
متن کامل