Analysis of Artificially Weathered PET and a Separate PET Hydrolysis Evaluation Using the 4300 Handheld FTIR Authors
نویسندگان
چکیده
Elucidating chemical changes in carbon fiber composites prior to physical degradation has been effectively demonstrated using handheld FTIR analyzers [1]. This application note shows that a handheld infrared spectrometer is equally effective at measuring early onset chemical changes in environmentally stressed PET polymer, which precede cracking and other physical degradation processes. This is an important issue in applications where polymers (as well as other materials such as paints and coatings) are exposed to environmental conditions varying from climatic conditions that depend on their geographic locale to complete submersion, as in the case of marine paints. The commercial availability of handheld FTIR spectrometers affords the capability of nondestructively measuring areas of large polymer sheets, as well as other coatings.
منابع مشابه
Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy
Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...
متن کاملEnzymatic surface modification and functionalization of PET: a water contact angle, FTIR, and fluorescence spectroscopy study.
The purpose of this study was to investigate the changes induced by a lypolytic enzyme on the surface properties of polyethylene terephthalate (PET). Changes in surface hydrophilicity were monitored by means of water contact angle (WCA) measurements. Fourier Transform Infrared spectroscopy (FTIR) in the Attenuated Total Reflectance mode (ATR) was used to investigate the structural and conformat...
متن کاملEvaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...
متن کاملImproved quantification of salivary gland scintigraphy by means of factor analysis
Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...
متن کاملIn vivo imaging of cellular proliferation in renal cell carcinoma using 18F-fluorothymidine PET
Objective(s): The ability to measure cellular proliferation non-invasively in renal cell carcinoma may allow prediction of tumour aggressiveness and response to therapy. The aim of this study was to evaluate the uptake of 18Ffluorothymidine (FLT) PET in renal cell carcinoma (RCC), and to compare this to 18F-fluorodeoxyglucose (FDG), and to an immunohistochemical measure of cellular proliferatio...
متن کامل