OCT corneal epithelial topographic asymmetry as a sensitive diagnostic tool for early and advancing keratoconus

نویسندگان

  • Anastasios John Kanellopoulos
  • George Asimellis
چکیده

PURPOSE To investigate epithelial thickness-distribution characteristics in a large group of keratoconic patients and their correlation to normal eyes employing anterior-segment optical coherence tomography (AS-OCT). MATERIALS AND METHODS The study group (n=160 eyes) consisted of clinically diagnosed keratoconus eyes; the control group (n=160) consisted of nonkeratoconic eyes. Three separate, three-dimensional epithelial thickness maps were obtained employing AS-OCT, enabling investigation of the pupil center, average, mid-peripheral, superior, inferior, maximum, minimum, and topographic epithelial thickness variability. Intraindividual repeatability of measurements was assessed. We introduced correlation of the epithelial data via newly defined indices. The epithelial thickness indices were then correlated with two Scheimpflug imaging-derived AS-irregularity indices: the index of height decentration, and the index of surface variance highly sensitive to early and advancing keratoconus diagnosis as validation. RESULTS Intraindividual repeatability of epithelial thickness measurement in the keratoconic group was on average 1.67 μm. For the control group, repeatability was on average 1.13 μm. In the keratoconic group, pupil-center epithelial thickness was 51.75±7.02 μm, while maximum and minimum epithelial thickness were 63.54±8.85 μm and 40.73±8.51 μm. In the control group, epithelial thickness at the center was 52.54±3.23 μm, with maximum 55.33±3.27 μm and minimum 48.50±3.98 μm epithelial thickness. Topographic variability was 6.07±3.55 μm in the keratoconic group, while for the control group it was 1.59±0.79 μm. In keratoconus, topographic epithelial thickness change from normal, correlated tightly with the topometric asymmetry indices of IHD and ISV derived from Scheimpflug imaging. CONCLUSION Simple, OCT-derived epithelial mapping, appears to have critical potential in early and advancing keratoconus diagnosis, confirmed with its correlation with established Scheimpflug-derived asymmetry topometric indices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior Segment Optical Coherence Tomography: Assisted Topographic Corneal Epithelial Thickness Distribution Imaging of a Keratoconus Patient

PURPOSE To evaluate safety, efficacy and ease of measurement of epithelial thickness in a keratoconic patient based on anterior segment optical coherence tomography (AS-OCT). METHODS A 25-year-old male patient, previously diagnosed with keratoconus, with highly asymmetric manifestation among the two eyes, was subjected to AS-OCT corneal epithelial imaging. We investigated epithelial thickness...

متن کامل

Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus.

PURPOSE To determine whether optical coherence tomography (OCT) epithelial mapping can improve the detection of form fruste keratoconus. SETTING French National Eye Hospital, Paris 6 Pierre & Marie Curie University, Paris, France. DESIGN Retrospective comparative study. METHODS Eyes with normal corneas, form fruste keratoconus, moderate keratoconus, or severe keratoconus were assessed usi...

متن کامل

Prediction of Corneal Condition After Corneal Ring Implantation in Keratoconus Patients

Background: Keratoconus is a common complication among corneal defects. As a result of expeditious and extensive progress of medical science in recent decades, corneal ring implantation has turned into a successful surgical procedure to correct the vision of Keratoconus patients; however, selecting the right patient is essential in the success of the operation. The prediction of corneal conditi...

متن کامل

Comparison of Corneal Epithelial and Stromal Thickness Distributions between Eyes with Keratoconus and Healthy Eyes with Corneal Astigmatism ≥2.0 D

PURPOSE To identify corneal epithelial- and stromal-thickness distribution patterns in keratoconus using spectral-domain optical coherence tomography (SD-OCT). PATIENTS AND METHODS We analyzed SD-OCT findings in 20 confirmed cases of keratoconus (group 1) and in 20 healthy subjects with corneal astigmatism ≥ 2 D (group 2). Epithelial and stromal thicknesses were measured at 11 strategic locat...

متن کامل

Risk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty

Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014