Ambulatory blood pressure measurement in the diagnosis and management of hypertension.

نویسندگان

  • E O'Brien
  • K O'Malley
  • F Mee
  • N Atkins
  • J Cox
چکیده

Before the diagnostic potential of 24-hour non-invasive BP measurement can be assessed, the accuracy of ambulatory recorders must be established, and normal reference values determined. The accuracy criteria of four ambulatory BP measuring systems (the SpaceLabs 90207, the Novecor DIASYS 200, the Takeda TM-2420 and the Del Mar Avionics Pressurometer IV) have been assessed according to the British Hypertension Society (BHS) protocol, and the Medilog, Suntech Accutracker II and the SpaceLabs 90202 according to the standard of the Association for the Advancement of Medical Instrumentation (AAMI). The SpaceLabs 90202 and 90207, the DIASYS 200 and the Medilog fulfilled the AAMI criteria. The best devices with the BHS grading system are the SpaceLabs 90207 and the DIASYS 200. Normal reference values for daytime, night-time and 24-hour ambulatory BP have been provided by the Allied Irish Bank study of 815 healthy individuals, which showed clear age and sex differences. The mean 24-hour ambulatory pressure for the entire group was 118/72 mm Hg. 24-hour ambulatory BP measurement possesses clear advantages over conventional clinic measurement in evaluating drug efficacy, as it provides many more readings, allowing for the possibility of reducing the number of patients in antihypertensive drug studies and eliminating the need for a placebo-controlled crossover design. It allows assessment of night-time BP, which is important in view of the fact that excessive BP reduction may put patients at risk of myocardial infarction.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resistant hypertension, case based approach to diagnosis and management: case report

Background: Resistant hypertension is defined when the blood pressure remains elevated above the therapeutic target levels despite the use of three antihypertensive agents including calcium channel blocker (CCB), renin-angiotensin system (RAS) blocker and a diuretic. These drugs should be used at maximally tolerated doses and white coat effect and non-adherence should also be excluded. In this ...

متن کامل

تازه های کاربرد هولتر مونیتورینگ 24 ساعته فشارخون درکودکان

  Background : There is always difficulty and inaccuracy in measurement of blood pressure by conventional method in children. Technical errors, human errors, and incompliance of child during measurements are the main disadvantage. Nowadays, 24- hour ambulatory blood pressure measurements (ABPM) are introduced to apply for children. The aim of this review is to update our understanding on the ac...

متن کامل

Effects of Ramadan fasting on ambulatory blood pressure in hypertensive patients

Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...

متن کامل

The role of twenty-four-hour ambulatory blood pressure measurement in clinical practice.

Twenty-four-hour ambulatory blood pressure monitoring is passing from research into clinical practice and it is necessary to clarify circumstances for which 24-h ambulatory measurement will be most beneficial. Devices should be accurate and reasonably priced. The operator should be able to interpret 24-h recordings and be familiar with the operation of the equipment. The subject must be capable...

متن کامل

Usefulness of ambulatory blood pressure monitoring in diagnosis of arterial hypertension in children and adolescents.

BACKGROUND Arterial hypertension in children and adolescents is an important medical problem with a prevalence rising over the last ten years from 1 to 4.5%. AIM To assess the usefulness of ambulatory blood pressure monitoring (ABPM) in diagnosis of arterial hypertension in children and adolescents. METHODS Two hundred and twelve children with elevated blood pressure (BP) and 81 healthy con...

متن کامل

The role of home and ambulatory blood pressure recording in the management of hypertension.

A review of the literature shows that doctor-recorded measurement (DRM) of blood pressure is higher than patient-recorded measurement (PRM) by either home-recording or ambulatory measurement. The role of home-recording and ambulatory measurement as a means of supplementing doctor-recorded measurement is discussed. The results of two studies comparing home-recording with clinic and ambulatory bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of human hypertension

دوره 5 Suppl 2  شماره 

صفحات  -