How to secure the connection between thoracostomy tube and drainage system?

نویسندگان

  • Ka Ki Pat Li
  • Kit Shing John Wong
  • Yau Hang Henry Wong
  • Ka Lok Cheng
  • Fung Ling So
  • Chu Leung Lau
  • Chak Wah Kam
چکیده

BACKGROUND Thoracostomy tube insertion is one of the common bedside procedures in emergency medicine and many acute specialties. Dislodgement of thoracostomy tube from the connection tube of chest drainage system is an important problem with potential complications such as contamination, infection and pneumothorax. Besides, mere loosening can also lead to malfunction. It is a common practice to tape the connection of the system. This study aimed to evaluate the materials and methods of connection of chest drain system to minimize drainage dislodgement. METHODS We conducted an experimental study to assess the tightness of the connection with various taping materials and methods. We selected three commonly used adhesive materials (3M™ Transpore™ Medical tape, 3M™ Micropore™ Medical tape, 3M™ Soft Cloth Tape on Liner) and three different methods (cross method, straight method, nylon band) to secure the junction between the thoracostomy tube and the bi-conical adaptor in the drainage system. The measured outcome was the weight causing visible loosening of the junction between thoracotomy tube and the adaptor. RESULTS For each taping material and taping method, 10 trials were performed. The median weight required to disconnect the junction is 26.22 lb for Transpore™, 31.29 lb for Micropore™ and 32.44 lb for Soft Cloth Tape on Liner. A smaller force was required to disconnect if Transpore™ is used (P<0.001). There was no statistical significant difference between Micropore™ and Soft Cloth Tape on Liner (P=0.98). The median disconnecting force is 32.44 lb for straight taping method, 40.55 lb for cross taping method and 21.15 lb for plastic band. The cross-taping method was the more secure method (P<0.0001 when compared with plastic band) (P=0.033 when compared with straight method). CONCLUSION Cross-taping is the most secure method among the tested varieties in connecting the thoracostomy tube to the chest drainage system. Transpore™ is not a recommended material for thoracostomy tube taping.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Necessity of routine thoracostomy tube insertion after transhiatal esophagectomy

Introduction: Transhiatal esophagectomy is a widely accepted approach for palliative resection of subcarinal esophageal cancers. This study was designed to evaluate the necessity of routine thoracostomy tube insertion in this technique.  Methods: This descriptive study was conducted on 123 consecutive patients with esophageal cancers undergoing transhiatal esophagectomy from March 2001 to Fe...

متن کامل

Simple tube thoracostomy versus surgical debridement in complicated parapneumonic empyema management

Background: Approach to treat empyema following pulmonary infection, especially in the second stage, is disputed. Therefore, this research aimed to compare the effect of simple tube thoracostomy versus surgical debridement in complicated parapneumonic empyema management. Methods: This prospective randomized trial was conducted in Thoracic Surgery Department of Imam Khomeini Hospital of Tabriz ...

متن کامل

Impact of positive pressure ventilation on thoracostomy tube removal in traumatic patients who admitted in ICU

Introduction: Few studies is in literature related to evaluation of impact of positive pressure ventilation (PPV) on thoracostomy tube removal in Iran. We decided, in this study, to evaluate the impact of PPV on recurrent pneumothorax (PTX) after removal of thoracostomy tubes (TT). Methods: A case-control study was performed for evaluating 122 chest tubes in 109 mechanically ventilatedtrauma pa...

متن کامل

Pigtail Tube Drainage as a Safe and Effective Alternative to Traditional Chest Tube Thoracostomy in Adults with Spontaneous Pneumothoraces: A Systematic Review

Background: Primary spontaneous pneumothorax occurs in young, healthy populations, usually males, in the absence of lung disease. Secondary spontaneous pneumothorax occurs in older adults who have underlying lung disease such as COPD, emphysema, or a malignant growth. The estimated incidence of spontaneous pneumothorax is 7.4 to 18 per 100,000 for males and 1.2 to 6 per 100,000 in females. Trad...

متن کامل

Comparison of the Amount of Air Leakage Into the Thoracic Cavity Associated with Three Thoracostomy Tube Materials in Canine Cadavers

This study was performed to compare the amount of air leakage into the thoracic cavity associated with three thoracostomy tube materials (silicone, polyvinyl chloride, red rubber) in canine cadavers. Differences in intrapleural pressures (IPPs) measured before and after tube placement and before and after tube removal were calculated. The duration of air leakage around the tubes was assessed by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • World journal of emergency medicine

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2014