Postsurgical contact dermatitis due to povidone iodine: a diagnostic dilemma.
نویسندگان
چکیده
We present 7 cases of postsurgical contact dermatitis due to povidone iodine. The diagnosis was based on the clinical manifestations, the history of exposure, the site of the lesions, and the results of patch tests. This type of dermatitis can develop in the area of surgery or at distant sites exposed to povidone iodine during the surgical intervention. Patch tests with 10% povidone iodine in petrolatum were positive in all patients. Based on the results of the same tests in a control group, we recommend the use of petrolatum rather than water as the vehicle for the diagnosis of this form of contact dermatitis. Repeated open application tests with a commercially available solution of povidone iodine were negative. We conclude that the presence of the solution under occlusion during surgery is necessary both for the symptoms to develop and for the diagnosis to be made. This condition may be underdiagnosed.
منابع مشابه
An unusual complication of late onset allergic contact dermatitis to povidone iodine in oral & maxillofacial surgery - a report of 2 cases.
BACKGROUND Povidone iodine (PVP-I) is a chemical complex of polyvinylpyrrolidone (also known as povidone or PVP) and elemental iodine. Iodine containing compounds are widely and commonly used as antiseptics and disinfectants. They are available in various forms like aqueous solution, tincture, aerosol, ointment, or foam. Skin irritation to them is due to the oxidative effects of iodine. Because...
متن کاملSevere irritant contact dermatitis induced by povidone iodine solution
Albeit uncommon occurrence, irritant contact dermatitis induced by povidone iodine can be an unfortunate adverse reaction complicating its use as an antiseptic. We hereby present the case report of a patient who suffered such a reaction as a result of exposure to povidone iodine, employed as an antiseptic during spinal anesthesia. On conservative management with soframycin ointment, the lesions...
متن کاملAllergic dermatitis caused by povidone iodine: an uncommon complication of chronic peritoneal dialysis treatment.
Allergic dermatitis around the catheter exit site, caused by topical antiseptics such as povidone iodine and chlorhexidine gluconate, is an uncommon complication in patients on chronic peritoneal dialysis (CPD). As yet, published reports concerning this rare non catheter-related complication are few. The frequency of this type of dermatitis is not known, because reports of isolated cases consti...
متن کاملProspective Single-Center Observational Study of the Allergenic Potential of Mercromina Film and Other Common Antiseptics in Patients With Contact Dermatitis.
INTRODUCTION Although Mercromina Film and other topical antiseptics are widely used, they are not included in the standard series recommended by the Spanish Contact Dermatitis and Skin Allergy Research Group for testing suspected allergic contact dermatitis (ACD). Furthermore, no recent studies have investigated the allergenic potential of merbromin. OBJECTIVE To determine the allergenic pote...
متن کاملAn Adverse Reaction in the Pediatric Sleep Laboratory
We present a case of a 15-month-old boy with Cornelia de Lange Syndrome (NIPBL gene mutation). On a PSG, central sleep apnea (central apnea-hypopnea index of 19/hour) and nocturnal hypoventilation (transcutaneous CO2 > 50 mmHg for 53% of the night) were found. A positive pressure initiation study was aborted because the patient developed a serious adverse reaction. The differential diagnosis in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Actas dermo-sifiliograficas
دوره 105 3 شماره
صفحات -
تاریخ انتشار 2014