Quality Assessment of Wild Atlantic Sturgeon Semen under Conditions of Short-Term Storage

نویسندگان

  • Kathryn M. Dorsey
  • Glenn R. Welch
  • Jerre Mohler
  • Daniel D. Theisen
  • Frank Siewerdt
  • Bryan T. Vinyard
چکیده

Short-term storage trials were conducted with semen of Atlantic sturgeon Acipenser oxyrinchus collected from a total of nine wild males during the 2008 and 2009 spawning seasons on the Hudson River. Semen samples were kept refrigerated (4 ± 1◦C) and stored in different gaseous atmospheres and storage extenders. The gaseous environments included oxygen, nitrogen, and air, while the extender treatments included modified Tsvetkova (MT), Park and Chapman (PC), and undiluted. Analyses of four response variables—percent viable sperm (viability), percent motile sperm (motility), curvilinear velocity (VCL), and ATP content—were determined on the day of arrival in the laboratory and then every other day for 7 d in 2008 and 21 d in 2009. The experiments were conducted in a split-split-plot design to examine dilution treatment, gas atmosphere, and repeated measures across days, and linear analyses of covariance models were fit to the data after appropriate transformation. Storage of sperm in an oxygen atmosphere was superior to storage in a nitrogen atmosphere for all variables. Storage of semen in 100% or 21% (air) oxygen in PC did not lead to differences among variables except for viability; viability was maintained at more than 95% through 13 d, decreasing to 88% and 94% on day 21 in 100% oxygen and air, respectively. During the last 5 d survival in an air atmosphere was better than that in 100% oxygen. Motility decreased during the 21 d of storage and the decline was greater in undiluted than in PC-extended semen, decreasing from 85% on day 1 to approximately 21% and 47%, respectively, on day 21. We conclude that for Atlantic sturgeon semen storage, PC is the extender of choice and semen viability can be maintained for up to 21 d with some expectation of successful fertilization. *Corresponding author: [email protected] Received October 30, 2010; accepted March 19, 2011

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of camel milk as an extender for short-term storage of ram semen at 15°C

The purpose of the present study was to assess the effect of modified camel milk (MCAM) and skim cow milk (SCOM) on semen quality of INRA180 and Boujaâd ram breeds, stored at 15°C for up to 24 hours. Semen samples were collected from eleven mature rams (6 from INRA180 and 5 from Boujaâd rams) and extended in SCOM vs MCAM, to reach a final concentration of 0.8×109 spermatozoa/mL, and stored at 1...

متن کامل

Effect of Semen Diluents and Dilution Rates on Motility of Guinea Fowl Spermatozoa Under Short-Term Storage

The assessment of spermatozoa motility is one of the most often used parameters for semen evaluation. The study was conducted at Poultry Research Station, Madhavaram Milk Colony, Chennai600 051, to  nd the effect of different semen diluents and dilution ratio on per cent spermatozoa motility of pooled guinea fowl semen at 5o C under short term storage(0, 3 and 6 Hours). Irrespective of the sto...

متن کامل

An analysis of Selected Aspects of Sperm Quality in Fresh and Cooled-Storage Stallion Semen

This review summarises the most significant findings related to the issue of the quantitative and qualitative indicators of stallion ejaculates, its processing when producing chilled insemination doses and the possibility of influencing the individual steps of the entire process. Artificial insemination, with cooled-storage semen, is increasingly used in horse breeding because it offers many ad...

متن کامل

Effects of long-term liquid commercial semen extender and storage time on the membrane quality of boar semen

The objective of this study was to assess the sperm membrane integrity in extended boar semen during storage time using specific spectrum laboratory methods. Boar semen was diluted with the long-term liquid commercial extenders Androhep (A), Androstar (AS), Androstar plus (AS+), LD and M III and was stored up to 96 h. The sperm membrane integrity was evaluated by motility, viable spermatozoa, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -