Characteristics: Ambient Pm10 Samplers
نویسندگان
چکیده
The National Ambient Air Quality Standards (NAAQS) for PM in terms of PM10 are ambient air concentration limits set by the EPA that should not be exceeded. Further, some state air pollution regulatory agencies (SAPRAs) utilize the NAAQS to regulate criteria pollutants emitted by industries by applying the NAAQS as property-line concentration limits. Prior to and since the inclusion of the PM10 standard, numerous journal articles and technical references have been written to discuss the epidemiological effects, trends, regulation, and methods of determining PM10. A common trend among many of these publications is the use of samplers to collect information on PM10. Often, the sampler data are assumed to be accurate measures of PM10. The fact is that issues such as sampler uncertainties, environmental conditions, and the characteristics of the materials that the sampler is measuring must be incorporated for accurate sampler measurements. The focus of this article is on the errors associated with particle size distribution (PSD) characteristics of the material in the air that is being sampled, PM10 sampler performance characteristics, the interaction between these two characteristics, and the effect of this interaction on the regulatory process. Theoretical simulations were conducted to determine the range of errors associated with this interaction for PM10 ambient air samplers. Results from the PM10 simulations indicated that a source emitting PM characterized by a mass median diameter (MMD) of 20 m and a geometric standard deviation (GSD) of 1.5 could be forced to comply with a PM10 standard that is 3.2 times more stringent than that required for a source emitting PM characterized by an MMD of 10 m and a GSD of 1.5, and 3.6 times more stringent than that required for a source emitting PM characterized by an MMD of 5.7 m and a GSD of 1.5. Therefore, in order to achieve equal regulation among differing industries, PM10 and PM2.5 measurements must be based on true concentration measurements.
منابع مشابه
Comparison of Two Ambient Beta Gauge PM10 Samplers.
This paper reports on the performance of the Kimoto 180 sampler and the Wedding ambient PM10 beta gauge sampler. Monodisperse ammonium fluorescein test particles were generated in the laboratory and used to determine the penetration curve of the Kimoto 180 cyclonic inlet. It was found that the actual DpaSOof the Kimoto 180 inlet, 3.5 (xm, is much lower than the designated standard value, 10 um....
متن کاملAgricultural Particulate Matter Emissions: Preliminary Study
The Federal Reference Method (FRM) ambient PM10 sampler does not always measure the true PM10 concentration. There are inherent sampling errors associated with the PM10 samplers due to the interaction of particle size distribution (PSD) and sampler performance characteristics. These sampling errors, which are the relative differences between theoretical estimation of the sampler concentration a...
متن کاملThe Design and Evaluation of a Low-volume Total Suspended Particulate Sampler
The regulation of particulate matter (PM) emitted by agricultural sources (cotton gins, feed mills, concentrated animal feeding operations (CAFOs) is based upon downwind concentrations of particulate matter less than 10 and 2.5 micrometers (μm) (PM10 and PM2.5) aerodynamic equivalent diameter (AED). Both PM10 and PM2.5 samplers operate by pre-separating PM larger than the size of interest (10 a...
متن کاملComparison of Tests for Equivalence of Methods for Measuring PM10 Dust in Ambient Air
Our paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on ‘on-site’ measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standar...
متن کاملParticle Size Distribution Analyses of Agricultural Dusts and Report of True PM10 Concentrations
This study presents the results of the particle size distribution (PSD) analyses of dusts from two agricultural facilities using filters from collocated PM10 and total suspended particulates (TSP) samplers. Ideally, PM10 concentrations obtained using the PM10 sampler should be the same as those using the TSP sampler. However, it was observed from numerous sampling episodes that there exists a b...