Correction of confidence intervals in excess relative risk models using Monte Carlo dosimetry systems with shared errors
نویسندگان
چکیده
In epidemiological studies, exposures of interest are often measured with uncertainties, which may be independent or correlated. Independent errors can often be characterized relatively easily while correlated measurement errors have shared and hierarchical components that complicate the description of their structure. For some important studies, Monte Carlo dosimetry systems that provide multiple realizations of exposure estimates have been used to represent such complex error structures. While the effects of independent measurement errors on parameter estimation and methods to correct these effects have been studied comprehensively in the epidemiological literature, the literature on the effects of correlated errors, and associated correction methods is much more sparse. In this paper, we implement a novel method that calculates corrected confidence intervals based on the approximate asymptotic distribution of parameter estimates in linear excess relative risk (ERR) models. These models are widely used in survival analysis, particularly in radiation epidemiology. Specifically, for the dose effect estimate of interest (increase in relative risk per unit dose), a mixture distribution consisting of a normal and a lognormal component is applied. This choice of asymptotic approximation guarantees that corrected confidence intervals will always be bounded, a result which does not hold under a normal approximation. A simulation study was conducted to evaluate the proposed method in survival analysis using a realistic ERR model. We used both simulated Monte Carlo dosimetry systems (MCDS) and actual dose histories from the Mayak Worker Dosimetry System 2013, a MCDS for plutonium exposures in the Mayak Worker Cohort. Results show our proposed methods provide much improved coverage probabilities for the dose effect parameter, and noticeable improvements for other model parameters.
منابع مشابه
Shared uncertainty in measurement error problems, with application to Nevada Test Site fallout data.
In radiation epidemiology, it is often necessary to use mathematical models in the absence of direct measurements of individual doses. When complex models are used as surrogates for direct measurements to estimate individual doses that occurred almost 50 years ago, dose estimates will be associated with considerable error, this error being a mixture of (a) classical measurement error due to ind...
متن کاملMonte Carlo Comparison of Approximate Tolerance Intervals for the Poisson Distribution
The problem of finding tolerance intervals receives very much attention of researchers and are widely used in various statistical fields, including biometry, economics, reliability analysis and quality control. Tolerance interval is a random interval that covers a specified proportion of the population with a specified confidence level. In this paper, we compare approximate tolerance interva...
متن کاملApplication of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom
Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...
متن کاملAccuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...
متن کاملEstimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods
Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...
متن کامل