Development, validation, and application of an acetylcholinesterase-biosensor test for the direct detection of insecticide residues in infant food.

نویسندگان

  • Holger Schulze
  • Ellen Scherbaum
  • Michelangelo Anastassiades
  • Sandra Vorlová
  • Rolf D Schmid
  • Till T Bachmann
چکیده

A highly sensitive and rapid food-screening test based on disposable screen-printed biosensors was developed, which is suitable for monitoring infant food. The exposure of infants and children to neurotoxic organophosphates and carbamates is of particular concern because of their higher susceptibility to adverse effects. The European Union has, therefore, set a very low limit for pesticides in infant food, which must not contain concentrations exceeding 10 microg/kg for any given pesticide. The maximum residue limit (MRL) has been set to be near the determination threshold that is typically achieved for pesticides with traditional analytical methods. The biosensor method could detect levels lower than 5 microg/kg and thus clearly fulfills the demands of the EU. To substantiate these measurements, recovery rates were determined and amounted on average to 104% in food. Matrix effects were eliminated by the introduction of a special electrode treatment. The test was compared with two traditional pesticide multiresidue analysis methods (GC-MS, LC-MS) using 26 fruit and vegetable samples from local markets and 23 samples of processed infant food from Germany, Spain, Poland and USA. Three infant food samples exceeded the MRL of 10 microg/kg when analyzed by either biosensor test or multiresidue methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Changeable Bioreactor for Detection of Organophosphate in a Flow-Through System

A flow-through biosensor consisting of a fixed bed bioreactor was employed to detect the insecticideparaoxon. Based on the inhibition of organophosphorous insecticide to the enzymatic activity of acetylcholinesterase (AChE), using paraoxon as a model compound, the condition for detection of the insecticide were optimized. The influence of enzyme loading on the packing surface was studied ...

متن کامل

Detection of Oxytetracycline Residue in Infant Formula by High-Performance Liquid Chromatography (HPLC)

Determination of drug residues in food is of great importance due to their toxicity. Long-term exposure with low level of drug residues could be important, especially in children. Based on document study, oxytetracycline (OTC) is a prophylaxis and treatment agent for great number of diseases and possesses a broad spectrum activity against many pathogenic organisms and can be toxic or cause alle...

متن کامل

Detection of Oxytetracycline Residue in Infant Formula by High-Performance Liquid Chromatography (HPLC)

Determination of drug residues in food is of great importance due to their toxicity. Long-term exposure with low level of drug residues could be important, especially in children. Based on document study, oxytetracycline (OTC) is a prophylaxis and treatment agent for great number of diseases and possesses a broad spectrum activity against many pathogenic organisms and can be toxic or cause alle...

متن کامل

Label-free electrochemical biosensors for food and drug application

In food sector, there is a huge demand for rapid, reliable, user & eco-friendly biosensors to analyse the quality and safety of food products. Biosensor based methodology depends upon the recognition of a specific antigens or receptors by corresponding antibodies, aptamers or high-affinity ligands. The first scientifically commercialised sensors were the electrochemical sensors used for the ana...

متن کامل

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 17 11-12  شماره 

صفحات  -

تاریخ انتشار 2002