[Evaluation of methods for monitoring air concentrations of hydrogen sulfide].
نویسندگان
چکیده
The development of different branches of industry and a growing fossil fuels minming results in a considerable emission of by-products. Major air pollutants are: CO, CO2, SO2, SO3, H2S, nitrogen oxides, as well as compounds of an organic arigin. The main aspects of this paper is to review and evaluate methods used for monitoring of hydrogen sulfide in the air. Different instrumental techniques were discussed, electrochemical, chromatographic and spectrophotometric (wet and dry), to select the method most suitable for monitoring low levels of hydrogen sulfide, close to its odor threshold. Based on the literature review the method for H2S determination in the air, involving absorption in aqueous zinc acetate and reaction with N,N-dimethylo-p-phenylodiamine and FeCl3, has been selected and preliminary verified. The adopted method allows for routine measurements of low concentration of hydrogen sulfide, close to its odor threshold in workplaces and ambient air.
منابع مشابه
The Performance of Compost Biofilter for Hydrogen Sulfide Removal from Contaminated Air
In order to evaluate the performance of biofilter for H2S removal from contaminated air, a 120×14 cm column biofilter was constructed using clear polyacrylic material in conjunction with H2S production and control systems. The column was divided into four stages using perforated plates. The column was packed with a mixture of mushroom compost and snail shell (4:1). The performance of biofilte...
متن کاملThe Performance of Compost Biofilter for Hydrogen Sulfide Removal from Contaminated Air
In order to evaluate the performance of biofilter for H2S removal from contaminated air, a 120×14 cm column biofilter was constructed using clear polyacrylic material in conjunction with H2S production and control systems. The column was divided into four stages using perforated plates. The column was packed with a mixture of mushroom compost and snail shell (4:1).
 The performance of biofil...
متن کاملDesign and evaluation of local ventilation system and packed bed scrubber and control of hydrogen sulfide emitted from the dryer lines of a Pulp Industry
Abstract Introduction: The diffusion of pollutants Methyl Mercaptan, Hydrogen Sulfide, Dimethyl sulfide and Dimethyl disulfide from dryer machines of pulp industries will cause to smell annoyance and health effects on the employees and neighbors . This study aimed to determine the effectiveness of local ventilation system and packed bed scrubber implemented for controlling the emitted hydrogen...
متن کاملInvestigation of hydrogen sulfide adsorption in metallic scaffold MOF-5 nanocomposite based on activated carbon for the use of respiratory mask cartridge
Introduction: Hydrogen sulfide is one of the most important impurities in natural gas. Due to the fact that this gas is hazardous, toxic, corrosive and volatile, therefore, the removal of hydrogen sulfide has been studied using several methods. One of the most known procedures is the adsorption process. In the present study, activated carbon and activated carbon-based composite scaffolds (MOF-5...
متن کاملEvaluation of Single Column Trapping/Separation and Chemiluminescence Detection for Measurement of Methanethiol and Dimethyl Sulfide from Pig Production
Reduced sulfur compounds are considered to be important odorants from pig production due to their low odor threshold values and low solubility in slurry. The objective of the present study was to investigate the use of a portable method with a single silica gel column for trapping/separation coupled with chemiluminescence detection (SCTS-CL) for measurement of methanethiol and dimethyl sulfide ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medycyna pracy
دوره 64 3 شماره
صفحات -
تاریخ انتشار 2013