Ballistic and diffuse light detection in confocal and heterodyne imaging systems

نویسندگان

  • M. Kempe
  • A. Z. Genack
چکیده

The detection of ballistic and diffuse light in confocal and heterodyne imaging systems in transillumination is studied experimentally and theoretically. We find an optimum pinhole size for ballistic light detection and diffuse light rejection for confocal imaging. The ratio of ballistic and diffuse light is found to be determined primarily by sample parameters and aberrations introduced by the sample. For sample and illumination characteristics that are typical for biomedical imaging, the limits of ballistic light detection in confocal imaging are close to the noise limits of standard detectors. Heterodyne detection with narrow-bandwidth light can extend these limits, depending on the spatial and the temporal coherence properties of the transmitted scattered light. © 1997 Optical Society of America. [S0740-3232(97)03501-1]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femtosecond transillumination optical coherence tomography.

We describe a new technique, femtosecond transillumination optical coherence tomography, for time-gated imaging of objects embedded in scattering media. Time gating is performed with a fiber-optic interferometer with femtosecond pulses and coherent heterodyne detection to achieve a 130-dB dynamic range. A confocal imaging arrangement provides additional spatial discrimination against multiply s...

متن کامل

Design and Manipulation 3D Imaging System by using Photodiode Grid

Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...

متن کامل

Early detection of intravascular large B-cell lymphoma by 18FDG-PET/CT with diffuse FDG uptake in the lung without respiratory symptoms or chest CT abnormalities

Intravascular large B-cell lymphoma (IVLBCL) is a rare and aggressive subtype of systemic extranodal non-Hodgkin diffuse large B-cell lymphoma (DLBCL). We report a rare case of IVLBCL who showed diffuse 18F-fluorodeoxyglucose (FDG) uptake in the lung in FDG-positron emission tomography/computed tomography (PET/CT) without respiratory symptoms or chest CT abnormalities. Serum biochemical studies...

متن کامل

Characterization of Coherence

This thesis discusses the development of a heterodyne based system designed to detect the coherent component of light transmitted through a turbid medium. The system can detect coherent light intensity as low as 100 dB of an initial sub-milliwatt level input beam. It employs a very narrow bandwidth approach for generating the required heterodyne signal so that the bandwidth of the detection is ...

متن کامل

Gated Frequency-Resolved Optical Imaging with an Optical Parametric Amplifier for Medical Applications

Implementation of optical imagery in a diffuse inhomogeneous medium such as biological tissue requires an understanding of photon migration and multiple scattering processes which act to randomize pathlength and degrade image quality. The nature of transmitted light from soft tissue ranges from the quasi-coherent properties of the minimally scattered component to the random incoherent light of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996