Laser Doppler imaging of skin microcirculation.
نویسندگان
چکیده
Laser Doppler imaging (LDI), a new technique which allows measurement of skin blood perfusion at a distance from the skin surface, was assessed methodologically in healthy volunteers. Each skin LDI value was based on virtually real-time measurements obtained from a number of discrete measuring sites. In scans made along the circumference of the lower arm, valid figures for LDI (as distinct from no output at all) were obtained in 8/8 measurements at 0 degrees inclination, and in 16/16 measurements at 7 degrees, 14 degrees, 22 degrees, 30 degrees and 38 degrees, respectively. Beyond this inclination a numerical output was obtained in only 9/16 of measurements at an inclination of 48 degrees, in 7/16 at 69 degrees, and in no more than 1/16 at 90 degrees. Values obtained at angles of inclination greater than 38 degrees fell within the relatively narrow range of values obtained at lesser angles of inclination. The findings are of interest since measuring sites of clinical importance may not be flat. Variability of measurement (coefficient of variation in per cent) was studied in the lower leg by performing LDI and conventional laser Doppler flowmetry (LDF) concomitantly. The coefficient of variation for measurements in one subject at rest was 13% for LDI vs. 19% for LDF, the corresponding interindividual coefficient of variation values being 25% vs. 28%. In response to heating, finger pulp perfusion increased by 55% as measured by LDI (p = 0.0051) and by 44% (p = 0.0756) as measured by LDF. In summary, the findings contribute to the validation of LDI for skin perfusion measurement.
منابع مشابه
Effects of some anesthetic agents on skin microcirculation evaluated by laser Doppler perfusion imaging in mice
BACKGROUND Anesthetic agents alter microcirculation, influencing tissue oxygenation and delivery of vital substrates. Laser Doppler perfusion imaging is a widespread technique in the field of microvascular research that can evaluate noninvasively and in real time the effects of environmental conditions, physical manipulations, diseases and treatments on peripheral perfusion. This study aims to ...
متن کاملReal-time full field laser Doppler imaging
We present a full field laser Doppler imaging instrument, which enables real-time in vivo assessment of blood flow in dermal tissue and skin. This instrument monitors the blood perfusion in an area of about 50 cm(2) with 480 × 480 pixels per frame at a rate of 12-14 frames per second. Smaller frames can be monitored at much higher frame rates. We recorded the microcirculation in healthy skin be...
متن کاملNon-invasive assessment of skin microvascular function in humans: an insight into methods.
For more than two decades, methods for the non-invasive exploration of cutaneous microcirculation have been mainly based on optical microscopy and laser Doppler techniques. In this review, we discuss the advantages and drawbacks of these techniques. Although optical microscopy-derived techniques, such as nailfold videocapillaroscopy, have found clinical applications, they mainly provide morphol...
متن کاملCapillary blood cell velocity in periulcerous regions of the lower leg measured by laser Doppler anemometry.
BACKGROUND The capillary blood flow of the nailfold can be measured by means of modern non-invasive techniques like the videocapillary microscope in vivo. To quantify the capillary blood cell velocity, apart from the nailfold capillaries, we used a new technique, the so-called laser Doppler anemometry (LDA). OBJECTIVE The present study investigated how far laser Doppler fluxmetry (LDF), trans...
متن کاملA Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
The laser speckle contrast imager (LSCI) provides a powerful yet simple technique for measuring microcirculatory blood flow. Ideal for blood dynamic responses, the LSCI is used in the same way as a conventional Laser Doppler Imager (LDI). However, with a maximum skin depth of approximately 1 mm, the LSCI is designed to focus on mainly superficial blood flow. It is used to measure skin surface a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta dermato-venereologica
دوره 78 2 شماره
صفحات -
تاریخ انتشار 1998