Atherosclerotic and thrombogenic neointima formed over sirolimus drug-eluting stent: an angioscopic study.

نویسندگان

  • Tomoaki Higo
  • Yasunori Ueda
  • Jota Oyabu
  • Katsuki Okada
  • Mayu Nishio
  • Akio Hirata
  • Kazunori Kashiwase
  • Nobuyuki Ogasawara
  • Shinichi Hirotani
  • Kazuhisa Kodama
چکیده

OBJECTIVES We sought to examine by angioscopy the neointima formation and thrombogenic potential of the neointima after deployment of a drug-eluting stent (DES). BACKGROUND Late stent thrombosis after DES implantation, a major safety concern, has been associated with poor strut coverage by neointima. Intracoronary angioscopy provides a method for visual evaluation of stent coverage by neointima and detection of thrombus in the stented coronary segment. METHODS Patients undergoing implantation of a sirolimus DES (n = 57) were serially examined by angioscopy immediately after (baseline) and again at 10 months (follow-up) after implantation. The angioscopic color grade of the neointima from white to yellow was assessed in a semiquantitative manner. Stent coverage was classified into not covered (Grade 0), covered by a thin layer (Grade 1), or buried under neointima (Grade 2). The thrombogenic potential of the neointima was evaluated by the prevalence of thrombus on the neointima. RESULTS The maximum yellow color grade of the neointima within DES-implanted lesions increased significantly from baseline to follow-up (1.4 +/- 1.1 vs. 1.9 +/- 0.6, p = 0.0008). Even among lesions without yellow color at baseline, yellow color was detected in 94% (17 of 18) of lesions at follow-up. The prevalence of thrombus was significantly higher on the yellow than on the white neointimal areas. Thrombus was detected on yellow and/or Grade-0/1 neointima, but never on the white Grade-2 neointima. CONCLUSIONS Sirolimus DES promoted formation of atherosclerotic yellow neointima in the stent-implanted lesion at 10-month follow-up. Thrombus was detected more often on the yellow area than on the white area and was never detected where a stent was buried under white neointima. These data suggest that the increased potential risk of late stent thrombosis in DES lesions may be due to the newly formed yellow neotima and cholesterol-laden plaque.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angioscopic Evaluation of Neointimal Coverage of Coronary Stents

Drug-eluting stents (DES) reduce coronary restenosis significantly; however, late stent thrombosis (LST) occurs, which requires long-term antiplatelet therapy. Angioscopic grading of neointimal coverage of coronary stent struts was established, and it was revealed that neointimal formation is incomplete and prevalence of LST is higher in DES when compared to bare-metal stents. It was also obser...

متن کامل

Lack of association between large angiographic late loss and low risk of in-stent thrombus: angioscopic comparison between paclitaxel- and sirolimus-eluting stents.

BACKGROUND It recently has been hypothesized that a larger late loss may have a protective role against stent thrombosis. The relationship between angiographic late loss and the presence of thrombus based on angioscopic findings within paclitaxel-eluting stents (PES) and sirolimus-eluting stents (SES) was investigated in this study. METHODS AND RESULTS Prospective 6-month follow-up angiograph...

متن کامل

Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents.

BACKGROUND The time course of neointimal formation after stent implantation has not been studied extensively by angioscopy in the drug-eluting stent era. METHODS AND RESULTS Serial angioscopic findings at first follow-up (3.6+/-1.1 months), second follow-up (10.5+/-1.6 months), and third follow-up (21.2+/-2.2 months) after stent implantation were compared between sirolimus-eluting stents (SES...

متن کامل

Evaluation of polymer-based comparator drug-eluting stents using a rabbit model of iliac artery atherosclerosis.

BACKGROUND Although atherosclerotic models, especially in the rabbit, have existed for a long time, a comparative study of various drug-eluting stent (DES) implantations in atherosclerotic arteries have not been systematically studied. METHODS AND RESULTS New Zealand White rabbits (n=44) with induced atheroma received bilateral iliac artery stents: bare metal stent (BMS) (Driver) or a stent e...

متن کامل

Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating.

OBJECTIVE The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. METHODS AND RESULTS The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 2 5  شماره 

صفحات  -

تاریخ انتشار 2009