Vein diameter after intraoperative dilatation with vessel probes as a predictor of success of hemodialysis arteriovenous fistulas
نویسندگان
چکیده
BACKGROUND Vascular access is "the life line" for patients on chronic hemodialysis. The autogenous arteriovenous fistula provides the best access to the circulation because of low complication rate, long-term use, and lower cost, compared to arteriovenous graft and central venous catheter. The primary objective of this prospective study was to investigate the predictive value of vein diameter after intraoperative dilatation with vessel probes on hemodialysis fistula maturation. MATERIAL AND METHODS Ninety-three fistulas were performed by a single surgeon from February 1, 2006 to January 31, 2009. Intraoperative vein dilatation with vessel probes was attempted in all fistulas. Measurements of the feeding artery diameter, vein diameter and the increased vein diameter after intraoperative dilatation were performed and immediate failure, early patency, early failure, primary patency, and fistula survival outcomes were recorded during 48-month follow-up. RESULTS Early failure occurred in 20% of fistulas and 70% matured sufficiently for cannulation. Variables with significant impact on the failure to mature by univariate analysis were: body-mass index (P=0.041), artery diameter (P<0.001), vein diameter (P=0.004), and vein diameter after dilatation (P=0.002). However, but multivariate analysis showed that only body-mass index (P=0.038), artery diameter (P=0.001), and the diameter of the vein after dilatation (P=0.018) significantly affected maturation. In a group of 56 (60%) patients with vein diameter before dilatation ≤ 2 mm, among vessel characteristics found by multivariate analysis, only vein diameter after dilatation (P=0.004) significantly affected function. CONCLUSIONS Artery diameter and vein diameter after intraoperative dilatation with vessel probes were the main predictors of fistula function.
منابع مشابه
برآورد عوامل موثر در شکست فیستول های شریانی-وریدی در بیماران همو دیالیزی مراجعه کننده به بیمارستان هاشمی نژاد با استفاده از مدل رگرسیونی درختی
Background: Hemodialysis is the sole way for management of patients with End Stage Renal Disorders (ESRD). Nowadays, inserting arteriovenous fistula is one of the most common methods for effective hemodialysis. Several factors have been reported for failure of arteriovenous fistulas such as diabetes, biochemical factors, low hemoglobin and increased level of blood calcium and phosphorus. Decisi...
متن کاملRisk factors predicting the successful function and use of autogenous arteriovenous fistulae for hemodialysis.
BACKGROUND For patients with end-stage renal failure hemodialysis with an autogenous arteriovenous fistula (AVF) has proven to be the ideal vascular access. OBJECTIVE The aim of this study is to discover potential predictors of a well-functioning hemodialysis fistula. METHODS From December 2009 to March 2011, 80 patients undergoing first time AVF creation were enrolled in our retrospective ...
متن کاملInfluence of arterial elasticity and vessel dilatation on arteriovenous fistula maturation: a prospective cohort study.
BACKGROUND Arteriovenous fistula maturation requires dilatation of the anastomosed artery and vein. The factors that affect dilatation and the mechanisms by which dilatation promotes maturation are not understood. This pilot study tested two hypotheses: that low arterial elasticity is associated with maturation failure, and that vessel dilatation is required for adequate fistula blood flow duri...
متن کاملThe experience use of drug-coated & non drug-coated balloons in arteriovenous fistula at a six months period: brief report
Background: The ineffectiveness of hemodialysis fistulas causes high costs and increases mortality and morbidity rates. The efficacy of drug-coated balloon and nondrug-coated balloon in dysfunctional arteriovenous Fistula was evaluated over six month period. Methods: In this randomized clinical trial, a total of a total of 50 hemodialysis patients who referred to Imam Reza Hospital in Kermansh...
متن کاملEndovascular Stent Placement of Juxtaanastomotic Stenosis in Native Arteriovenous Fistula After Unsuccessful Balloon Angioplasty
BACKGROUND In hemodialysis patients, the most common problem in arteriovenous fistulas, as the best functional vascular access, is the juxtaanastomotic located lesions. Percutaneous transluminal angioplasty is accepted as the treatment method for juxtanastomotic lesions. OBJECTIVES To assess juxtaanastomotic stent placement after insufficient balloon angioplasty in the treatment of autogenous...
متن کامل