Physiologic impact of closed-system endotracheal suctioning in spontaneously breathing patients receiving mechanical ventilation.

نویسندگان

  • Christopher W Seymour
  • Brian J Cross
  • Colin R Cooke
  • Robert L Gallop
  • Barry D Fuchs
چکیده

BACKGROUND Endotracheal suctioning is required but can have adverse effects, and could affect cardiorespiratory variables that are used to predict whether the patient is ready for extubation. METHODS In a prospective cohort study in a university hospital's medical intensive care unit, we measured the impact of closed-system suctioning on cardiopulmonary variables in spontaneously breathing patients weaning from mechanical ventilation. All spontaneously breathing, mechanically ventilated patients were screened for enrollment at the initiation of weaning from mechanical ventilation. Before, during, and after standardized closed-system endotracheal suctioning we measured minute volume, heart rate, arterial oxygen saturation, mean arterial pressure, respiratory frequency, oxygen saturation, and tidal volume. RESULTS Twenty-nine patients were enrolled after a median of 5 (interquartile range [IQR] 3-9) ventilator days. Twenty-five patients (86%) were spontaneously breathing on pressure-support ventilation when suctioned. The median post-suctioning recovery time was > 5 min for minute volume, tidal volume, respiratory rate, and ratio of respiratory rate to tidal volume. The post-suctioning median values of the maximum deviations in the ventilatory variables were clinically important: minute volume -2.4 (IQR 1.6-3.7) L/min, respiratory rate 8 (IQR 2-14) breaths/min, tidal volume -175 (108-220) mL. Heart rate, mean arterial pressure, and oxygen saturation increased after suctioning (P < .05), but the increases were not clinically important. CONCLUSIONS Post-suctioning changes in the measured variables persisted longer in these spontaneously breathing patients weaning from mechanical ventilation than in patients who are sedated and paralyzed. The effects of suctioning on cardiopulmonary function should be considered in practice and during the design of future studies on weaning and extubation prediction variables.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Indicators for Endotracheal Suctioning in Adult Patients Receiving Mechanical Ventilation.

BACKGROUND Critically ill patients who need mechanical ventilation require endotracheal suctioning. Guidelines recommend coarse crackles over the trachea and/or the presence of a sawtooth pattern on the flow-volume loop of the ventilator waveform as the best indicators. OBJECTIVE To determine clinical cues for endotracheal suctioning in patients who require mechanical ventilation. METHODS A...

متن کامل

Comparison of the Effects of Open and Closed Endotracheal Suction on Cardiovascular and Ventilation Parameters for Patients Undergoing Mechanical Ventilation

Background and Objectives: Suction is a necessary and common method which aids in the release of secretion from the respiratory system for the patients who have undergone mechanical ventilation. One of the most common complications of suction is hypoxemia which causes dysrhythmia and death. The purpose of this study was to determine the effects of open and closed-endotracheal suction on cardiov...

متن کامل

مقایسه تاثیر دو روش ساکشن باز و بسته بر دیس ریتمی های قلبی بیماران تحت تهویه مکانیکی

Background: Nowadays, due to an increase in patients require intensive care, application of mechanical ventilation and endotracheal tube is necessary. In order to Keeping an open airway, endotracheal suctioning is necessary. Select the appropriate suction method can reduce the severe complications. The aim of this study is comparing the efficacy of open and closed suctioning on heart disrhythmi...

متن کامل

Comparing the effect of open and closed endotracheal suctioning on pain and oxygenation in post CABG patients under mechanical ventilation

BACKGROUND The aim of this study was to compare changes in pain, oxygenation, and ventilation following endotracheal suctioning with open and closed suctioning systems in post coronary artery bypass grafting (CABG) patients. MATERIALS AND METHODS 130 post CABG mechanically ventilated patients were randomly allocated to undergo either open (n = 75) or closed (n = 55) endotracheal suctioning fo...

متن کامل

تأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی

  Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2009