Automatic bone removal for 3D TACE planning with C-arm CBCT: Evaluation of technical feasibility.

نویسندگان

  • Zhijun Wang
  • Eberhard Hansis
  • Rongxin Chen
  • Rafael Duran
  • Julius Chapiro
  • Yun Robert Sheu
  • Hicham Kobeiter
  • Michael Grass
  • Jean-François Geschwind
  • MingDe Lin
چکیده

PURPOSE To evaluate the technical feasibility of automatically removing the ribs and spine from C-arm cone-beam computed tomography (CBCT) images acquired during transcatheter arterial chemoembolization (TACE). MATERIAL AND METHODS Fifty-eight patients (45.8 ± 5.0 years) with unresectable hepatocellular carcinoma (HCC) underwent transcatheter arterial chemoembolization and had intraprocedural CBCT imaging. Automatic bone removal was performed using model-based segmentation of the ventral cavity. Two interventional radiologists independently evaluated the performance of bone removal, remaining soft tissue retention, and general usability (where both the bone is appropriately removed while retaining soft tissue) for 3D TACE planning on a four-level (complete/excellent, adequate/good, incomplete/questionable, insufficient/bad) score. The proportion of inter-reader agreement was calculated. RESULTS For ribs and spine removal, 98.3-100% and 100% of cases showed complete or adequate performance, respectively. In 96.6% of the cases, soft tissue was at least adequately retained. 91.3-93.1% of the cases demonstrated good or excellent general usability for TACE planning. Satisfactory inter-reader agreement proportion was achieved in ribs (93.1%) and spine removal (89.7%), soft tissue retention (84.5%), and general usability for TACE planning (72.4%). CONCLUSION Intraprocedural automatic bone removal on CBCT images is technically feasible and offers good removal of ribs and spine while preserving soft tissue. Its clinical value needs further assessment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative cone-beam CT for head and neck surgery: feasibility of clinical implementation using a prototype mobile C-arm.

BACKGROUND Intraoperative 3-dimensional (3D) imaging in head and neck surgery was developed using a prototype mobile C-arm for cone-beam CT (CBCT). This article summarizes its implementation in a prospective pilot and feasibility study. METHODS The CBCT C-arm was used in 12 head and neck surgical oncology cases. Human-factors engineering methods and expert feedback from surgeons, nurses, and ...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

A feasibility study on the use of MV-CBCT images for urgent palliative treatment planning

Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...

متن کامل

Target localization of 3D versus 4D cone beam computed tomography in lipiodol-guided stereotactic radiotherapy of hepatocellular carcinomas

BACKGROUND Aim of this study was to comparatively evaluate the accuracy of respiration-correlated (4D) and uncorrelated (3D) cone beam computed tomography (CBCT) in localizing lipiodolized hepatocellular carcinomas during stereotactic body radiotherapy (SBRT). METHODS 4D-CBCT scans of eighteen HCCs were acquired during free-breathing SBRT following trans-arterial chemo-embolization (TACE) wit...

متن کامل

Architecture of a high-performance surgical guidance system based on C-arm cone-beam CT: software platform for technical integration and clinical translation

Intraoperative imaging modalities are becoming more prevalent in recent years, and the need for integration of these modalities with surgical guidance is rising, creating new possibilities as well as challenges. In the context of such emerging technologies and new clinical applications, a software architecture for cone-beam CT (CBCT) guided surgery has been developed with emphasis on binding op...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 2016