The effect of yield damage on the viscoelastic properties of cortical bone tissue as measured by dynamic mechanical analysis.
نویسندگان
چکیده
We have previously shown, using Dynamic Mechanical Analysis (DMA), that the presence of a defect in cortical bone tissue affects the apparent viscoelastic properties of that bone. However, mechanically induced damage is more complex than a machined defect making it difficult to predict its effect on bone viscoelasticity. We performed DMA measurements before and after introduction of yield damage into cortical bone beams from sheep radii. The specimens were placed in a DMA machine and baseline measurements of storage modulus (E1) and loss factor (tandelta) were performed using a 3-point bending configuration for a frequency range of 1-10 Hz. Measurements were done in all four bending directions (cranial, caudal, medial, and lateral) in random order. After subjecting the specimens to monotonic yield damage in a servohydraulic testing machine with the load applied to the cranial surface, oscillatory tests were repeated. To supplement results from the current experiment, additional analyses were performed on data from experiments where bone was either cut or fatigue-loaded between viscoelasticity measurements. Introduction of mechanical damage increased tan delta and frequency sensitivity of E1, consistent with the assertion that increased energy dissipation in damaged bone might contribute to its increased resistance to fatigue and fracture.
منابع مشابه
Apparent viscoelastic anisotropy as measured from nondestructive oscillatory tests can reflect the presence of a flaw in cortical bone.
There is evidence that damage, viscoelastic stiffness properties, and postyield mechanical properties are related in bone tissue. Our objective was to test whether presence of a flaw would have an influence on the apparent viscoelastic properties of bone. Examining the effect of flaw orientation on apparent viscoelastic properties and utilization of dynamic mechanical analysis (DMA) as a nondes...
متن کاملDynamic response determination of viscoelastic annular plates using FSDT – perturbation approach
In this paper, the transient response of a viscoelastic annular plate which has time-dependent properties is determined mathematically under dynamic transverse load. The axisymmetric conditions are considered in the problem. The viscoelastic properties obey the standard linear solid model in shear and the bulk behavior in elastic. The equations of motion are extracted using Hamilton’s principle...
متن کاملSynthesis and Investigation on Viscoelastic Properties of Urethane Acrylate- Polyaniline
The aim of this research is to investigate the viscoelastic behavior and determination of cross-link density of thin conductive coatings of urethane acrylate-polyaniline. For this purpose, polyaniline and urethane acrylate resin were synthesized. Nanocomposites with different percentages of polyaniline (1, 3, and 5%) were prepared and cured by ultraviolet irradiation. The viscoelastic prope...
متن کاملNatural Frequency and Dynamic Analyses of Functionally Graded Saturated Porous Beam Resting on Viscoelastic Foundation Based on Higher Order Beam Theory
In this paper, natural frequencies and dynamic response of thick beams made of saturated porous materials resting on viscoelastic foundation are investigated for the first time. The beam is modeled using higher-order beam theory. Kelvin-voight model is used to model the viscoelastic foundation. Distribution of porosity along the thickness is considered in two different patterns, which are symme...
متن کاملA Computational study on the effect of different design parameters on the accuracy of biopsy procedure
Needle insertion is a minimally invasive technique in diagnosing and treating tumors. However, to perform a surgery accurately, the tissue should have minimum amount of displacement during needle insertion so that it reaches the target tissue. Therefore, the tissue membrane has to move less to decrease rupturing under the membrane. In this study, the effect of different design parameters on dis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research. Part A
دوره 82 3 شماره
صفحات -
تاریخ انتشار 2007