Synthetic graft for reconstruction of middle hepatic vein tributaries in living-donor liver transplant.

نویسندگان

  • Refaat Kamel
  • Yasser Hatata
  • Karim Hosny
  • Khaled Amer
  • Mohamed Taha
چکیده

OBJECTIVES In middle hepatic vein dominant livers, the anterior segment of the right lobe of the liver (segments V and VIII) drains mainly into the middle hepatic vein. In these donors, when right lobe grafts are procured without the middle hepatic vein, the graft may harbor large segment V and/or VIII veins that need reconstruction to avoid graft congestion and subsequent graft dysfunction. Draining these middle hepatic vein tributaries using autologous or cryopreserved vessels is a solution, despite the possible difficulties of their preparation. However, these vessels are not always available. Our objective was to evaluate the effectiveness and safety of using a synthetic vascular graft. MATERIALS AND METHODS Between January 2012 and October 2013, eighteen adult recipients underwent living-donor liver transplant using right lobe grafts without the middle hepatic vein at Dar Al Fouad Hospital, 6th of October City, Egypt. All grafts had a large tributary of the middle hepatic vein. Eight-mm ringed expanded polytetrafluoroethylene vascular grafts were used to drain 15 segment V vein tributaries and 3 segment VIII vein tributaries directly to the inferior vena cava. Follow-up was done using duplex ultrasound to evaluate the patency of the vascular graft and the liver congestion and the liver function tests including liver enzymes. RESULTS Intraoperative Duplex ultrasound confirmed patency and absent segmental congestion in all 18 recipients. The vascular graft patency was 17/18 at 1 week (94.4%) and 15/18 at 1 month (83.3%). No recipients developed graft infection at 1 month. CONCLUSIONS Synthetic vascular expanded polytetrafluoroethylene grafts could be used effectively and safely in middle hepatic vein tributary reconstruction to overcome the unavailability of autologous or cryopreserved vessel grafts or just to avoid the additional burden of recovering autologous grafts thus simplifying the procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of 3-dimensional computed hepatic venous visualization for graft outflow venoplasty in adult left living-donor liver transplant.

OBJECTIVES A surgeon must be aware of hepatic vascular variations to safely perform living-donor liver transplant. The ramification patterns of the hepatic veins with tributaries for left lobe graft outflow venoplasty should be evaluated preoperatively with 3-dimensional computed tomography of the donor. MATERIALS AND METHODS Twenty-four potential donors were examined between October 1999 and...

متن کامل

Vein reconstruction in modified right liver graft for living donor liver transplantation.

OBJECTIVE To report the authors' experience with hepatic vein reconstruction and plasty in living donor liver transplantation for adult patients. SUMMARY BACKGROUND DATA A right liver graft without the middle hepatic vein (MHV) trunk (modified right liver graft) can cause severe congestion of the right paramedian sector. However, the need for MHV reconstruction has not been fully recognized. ...

متن کامل

Preoperative simulation with a 3-dimensional printed solid model for one-step reconstruction of multiple hepatic veins during living donor liver transplantation.

Meticulous preoperative volumetry of the partial liver graft is essential for both assessing the postoperative graft function and to ensure the donor safety in the field of living donor liver transplantation (LDLT). We herein report the case of a 53-year-old patient who underwent LDLT for hepatitis C virusinfected liver cirrhosis complicated with hepatocellular carcinoma. Preoperative 3D images...

متن کامل

Venous Outflow Reconstruction in Adult Living Donor Liver Transplant: Outcome of a Policy for Right Lobe Grafts without the Middle Hepatic Vein

Introduction. The difficulty and challenge of recovering a right lobe graft without MHV drainage is reconstructing the outflow tract of the hepatic veins. With the inclusion or the reconstruction of the MHV, early graft function is satisfactory. The inclusion of the MHV or not in the donor's right lobectomy should be based on sound criteria to provide adequate functional liver mass for recipien...

متن کامل

Two-step hepatic artery reconstruction for a hepatic artery lacking in length for the use of a microclamp in living donor liver transplantation

INTRODUCTION We describe successful two-step hepatic artery reconstruction in a patient whose graft site hepatic artery was too short for the use of a microclamp in living donor liver transplantation. PRESENTATION OF CASE A 57-year-old woman was diagnosed as having hepatitis C and liver cirrhosis. Her 26-year-old son was the living liver donor. The living donor underwent right lobectomy. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental and clinical transplantation : official journal of the Middle East Society for Organ Transplantation

دوره 13 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015