Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics.
نویسندگان
چکیده
PURPOSE To investigate the diurnal variation in axial length and anterior eye biometrics, while simultaneously measuring intraocular pressure (IOP) with dynamic contour tonometry in human subjects. METHODS Fifteen young adult near-emmetropic subjects had axial length, anterior eye biometrics (central corneal thickness and anterior chamber dimensions), and IOP measured at six different times across a 24-hour measurement period. Repeated-measures ANOVA and sine curve fitting were used to analyze the diurnal rhythms in each measured parameter. RESULTS Axial length was found to undergo significant diurnal variation (P = 0.0006). The mean amplitude of axial length change was 0.046 +/- 0.022 mm. The mean peak in axial length was found to occur at 1113. Intraocular pressure and ocular pulse amplitude were also found to undergo significant diurnal change (P < 0.0001 and 0.0006, respectively). The variation in axial length exhibited a significant association with the change in IOP (r = 0.37, P = 0.001). No significant difference was found between the mean peak times of axial length and IOP. Anterior eye biometric measures of central corneal thickness and anterior chamber depth were also found to undergo significant diurnal changes (P < 0.0001 and 0.0368, respectively). CONCLUSIONS Axial length undergoes significant variation over a 24-hour period. Associations exist between the change in axial length and the change in IOP, as measured by dynamic contour tonometry. These results may have significant implications for the role of ocular diurnal rhythms in emmetropization.
منابع مشابه
Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics.
PURPOSE To investigate the pattern of diurnal variations in axial length (AL), choroidal thickness, intraocular pressure (IOP), and ocular biometrics over 2 consecutive days. METHODS Measurements of ocular biometrics and IOP were collected for 30 young adult subjects (15 myopes, 15 emmetropes) at 10 different times over 2 consecutive days. Five sets of measurements were collected each day at ...
متن کاملThe Correlation between Glucose and Lipid Biomarkers Variations with biometric characteristics and Intraocular Pressure Changes during Ramadan Fasting
Introduction: The aim of present study was to assess the correlation between glucose and lipid biomarkers variations with biometric characteristics and intraocular pressure changes following Ramadan fasting. Methods: A total of 100 healthy fasting volunteers were enrolled in the study. Of them, 89 subjects completed the study with respect to inclusion and exclusion criteria. Right eye ocular ax...
متن کاملIncreased 24-hour variation of human intraocular pressure with short axial length.
PURPOSE To characterize 24-hour variation of intraocular pressure (IOP) in healthy young adults based on the axial length of the eye. METHODS Twenty-four-hour IOP data were collected from nine healthy young adults with hyperopia, age range 18 to 25 years, in a sleep laboratory. Every 2 hours, measurements of IOP were taken in the participants after 5 minutes in the supine position and 5 minut...
متن کاملDiurnal Intraocular Pressure with Bimatoprost/Timolol Fixed Combination versus Latanoprost/Timolol Fixed Combination in Healthy Subjects
PURPOSE To evaluate the effects of a bimatoprost/timolol fixed combination (BTFC) and a latanoprost/timolol fixed combination (LTFC) on diurnal intraocular pressure (IOP) and anterior ocular parameters in healthy subjects. METHODS We enrolled 58 healthy subjects in this prospective clinical study. Thirty subjects were treated with BTFC and 28 subjects were treated with LTFC. IOP was measured ...
متن کاملIntraocular pressure and ocular biometric parameters changes in migraine
BACKGROUND The aim of this study was to assess the intraocular pressure and ocular biometric parameters in migraine patients during acute migraine attacks and compare them with painless period and healthy controls using a new optical biometer AL-Scan. METHODS In this prospective, case-control study, the axial length, corneal curvature radius, anterior chamber depth, central corneal thickness,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 49 7 شماره
صفحات -
تاریخ انتشار 2008