Sensitivity and spatial resolution of square loop SQUID magnetometers

نویسنده

  • S Rombetto
چکیده

We calculate the flux threading the pick-up coil of a square SQUID magnetometer in the presence of a current dipole source. The result reproduces that of a circle coil magnetometer calculated by Wikswo [1] with only small differences. However it has a simpler form so that it is possible to derive from it closed form expressions for the current dipole sensitivity and the spatial resolution. The results are useful to assess the overall performance of the device and to compare different designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HTS dc-SQUID flip-chip magnetometers and gradiometers

Biomagnetic research requires measuring systems with the utmost sensitivity to magnetic fields. The strongest challenge is fMEG measurements with a typical (20 – 200) fT peak-to-peak signal magnitude. An average R-wave magnitude of a fMCG signal is ∼2 pT. Measuring in a frequency bandwidth of about 100 Hz with a signal-to-noise ratio of ∼10 demands a system noise for fMCG measurements ∼20 fT/√H...

متن کامل

Superconducting Quantum Interferometers for Nondestructive Evaluation

We review stationary and mobile systems that are used for the nondestructive evaluation of room temperature objects and are based on superconducting quantum interference devices (SQUIDs). The systems are optimized for samples whose dimensions are between 10 micrometers and several meters. Stray magnetic fields from small samples (10 µm-10 cm) are studied using a SQUID microscope equipped with a...

متن کامل

Scanning SQUID susceptometers with sub-micron spatial resolution.

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achie...

متن کامل

Ultimate limitation of the SQUID magnetometer

The Superconducting QUantum Interference Device is used to detect weak biomagnetic signals since in the early seventies. In that time the measurement was based on point contact rf SQUIDs operated at 20 MHz, with to a flux noise of the order of 10-4 Φ 0/ √Hz . After finding methods to fabricate reliable thin-film devices, the dc SQUIDs started gradually replace the rf SQUIDs. [1] The dc SQUID wi...

متن کامل

THESIS FOR THE DEGREE OF DOCTOR OF PHILOSOPHY Development of high-T c SQUID magnetometers for on-scalp MEG

This thesis describes the development of high critical temperature superconducting quantum interference device (high-Tc SQUID) magnetometers based on bicrystal grain boundary and nanowire junctions for the potential use in on-scalp magnetoencephalography (MEG), which is a new generation MEG technique with reduced sensor-to-subject standoff distances. MEG is a method of mapping neural dynamics i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008