Comparison between the PlusoptiX and IScreen Photoscreeners in Detecting Amblyopic Risk Factors in Children
نویسندگان
چکیده
Purpose: To compare the accuracy of plusoptiX A08 photoscreener (PPS) and iScreen 3000 photoscreener (IPS) in objectively screening for amblyopic risk factors in children age 5 months to 13 years old. Methods: Cross-sectional study of 148 children who received photoscreenings via PPS and IPS and a comprehensive pediatric ophthalmic examination in our office. Patients were considered to have amblyogenic risk factors based on the AAPOS referral criteria guidelines. Results: 45 percent of patients undergoing a pediatric ophthalmology examination were found to have amblyopia or amblyogenic risk factors. In this study, PPS demonstrated an overall sensitivity of 75.4%, specificity of 68.0%, positive predictive value (PPV) of 67.1%, and negative predictive value (NPV) of 76.1%. However, IPS photoscreener had an overall sensitivity of 66.2%, specificity of 87.6%, PPV of 81.8%, and NPV of 75.5%. Discussion: The accuracy of PPS and IPS was compared in different age groups. The sensitivity and specificity were analyzed according to varied amblyogenic risk factors. The statistic results of this study were compared to those of previous studies, including Vision in Preschoolers (VIP) Study and the Iowa PhotoScreening Program. Conclusion: PPS and IPS proved to be useful tools in the objective vision screening in children. PPS was found to have a higher sensitivity, and IPS showed a higher specificity and PPV in detecting amblyopic risk factors. In conclusion, one device may be more beneficial over the other, depending on the patient population and office settings.
منابع مشابه
Performance of four new photoscreeners on pediatric patients with high risk amblyopia.
PURPOSE A new study by the American Academy of Pediatrics touts the benefits of photoscreening, especially in preverbal children who cannot yet perform monocular acuity screening. Emerging devices have not been compared in young and developmentally challenged children. METHODS Consecutive patients in a pediatric eye practice had a comprehensive eye examination and four photoscreens: PlusoptiX...
متن کاملComparison between the plusoptiX and MTI Photoscreeners.
OBJECTIVE Both the Medical Technology and Innovations (MTI) and plusoptiX photoscreeners are used to objectively screen for amblyogenic risk factors in children. The MTI has been extensively studied, but the limited availability of film may render it obsolete. We compared the MTI with the plusoptiX, a newer digital photoscreener, for the ability to detect amblyogenic factors when compared with ...
متن کاملPerformance of the Plusoptix A09 Photoscreener in Detecting Amblyopia Risk Factors in Chinese Children Attending an Eye Clinic
PURPOSE To assess the accuracy of the Plusoptix A09 photoscreener in detecting amblyopia risk factors in children and determine referral criteria when using Plusoptix A09 for a large-scale vision screening. METHODS Pediatric patients attending our eye clinic underwent a comprehensive ophthalmic examination that included photorefraction, orthoptic examination, anterior segment assessment, fund...
متن کاملAccuracy of PlusOptix A09 distance refraction in pediatric myopia and hyperopia
BACKGROUND The PlusOptix photoscreeners (PlusOptix GmbH, Nuremberg, Germany) is used in many vision screening programs. The purpose of the present study was to further explore the accuracy of the PlusOptix A09 photoscreener in children with ametropia (myopia or hyperopia). METHODS A total of 70 eyes (35 children) were prospectively included. Before administration with the cycloplegia treatmen...
متن کاملComparison of preschool vision screening tests as administered by licensed eye care professionals in the Vision In Preschoolers Study.
PURPOSE To compare 11 preschool vision screening tests administered by licensed eye care professionals (LEPs; optometrists and pediatric ophthalmologists). DESIGN Multicenter, cross-sectional study. PARTICIPANTS A sample (N = 2588) of 3- to 5-year-old children enrolled in Head Start was selected to over-represent children with vision problems. METHODS Certified LEPs administered 11 common...
متن کامل