Optimized atomic absorption spectrophotometry of calcium in erythrocytes.
نویسندگان
چکیده
We sought to establish optimum conditions for measuring calcium in erythrocytes by atomic absorption spectrophotometry. The conditions we selected are as follows. Wash one volume of fresh heparin-treated packed cells once with 30 volumes of isotonic buffered saline (pH 7.4) at a temperature somewhat exceeding 25 degrees C. Dilute the washed packed cells 10-fold with 12 mmol/L hydrochloric acid, and analyze the supernate for calcium. Measure the hematocrit of the washed packed cells, then analyze an aliquot of them for calcium, using a computer-readout type of flame or a non-flame atomic absorption spectrophotometer equipped with a pyrocoated graphite tube. The temperature program is 1000 degrees C for ashing [corrected] and 1800 degrees C for the atomizing cycle. Intraday and day-to-day reproducibility of the assay was 6.55% and 8.19%, respectively, at the mean concentration of calcium in the erythrocytes of healthy adults, which is 4.30 mumol/L.
منابع مشابه
Zinc in plasma, neutrophils, lymphocytes, and erythrocytes as determined by flameless atomic absorption spectrophotometry.
Zinc is determined in neutrophils and lymphocytes (isolated from whole blood on discontinuous gradients of Ficoll-Hypaque) and in microliter quantities of plasma and erythrocytes by flameless atomic absorption spectrophotometry with greater sensitivity than with conventional flame atomic absorption spectrophotometry. Before analysis, neutrophils and lymphocytes are digested with nitric acid and...
متن کاملApplication of Atomic Absorption Spectrophotometry in the Determination of Calcium in Serum.
Atomic absorption spectrophotometry (AAS) was applied to the determination of serum calcium. A special diluent was developed to abolish the effect of absorption depressors. This made possible measurement of calcium in directly diluted serum samples without prior removal of any serum constituents. Values obtained by AAS on calcium oxalate precipitates from serum were identical with those found b...
متن کاملSpectrophotometric determination of Dalacin phosphate from formulations using reduce atomic absorption of calcium ion by phosphate
A simple, sensitive and accurate method for spectrophotometric determination of Dalacinphosphatehas been established. The method is based on the reduction of atomic absorptioncalcium ion by phosphate. Because, there is a phosphate mole in every Dalacin mole structureand with measurement of phosphate, Dalacin is beyond measurement too. Therefore, the reactionbetween acidic hydrolysis products of...
متن کاملMeasurement of total calcium in serum by atomic absorption spectrophotometry, with use of a strontium internal reference.
A method for total calcium in serum was optimized, a dual double-beam atomic absorption spectrophotometer being used, with strontium as an internal reference. The effect of HCI and lanthanum concentrations on the signals of both calcium and strontium was determined. The final analysis was unaffected by known sources of interference in serum at a 50-fold dilution of serum in 50mmolar HCI contain...
متن کاملNormal serum calcium levels by atomic absorption spectroscopy.
THE INITIAL STUDIES BY WILLIS (2, 3) and the more recent work of Zettner and Seligson (i) and others (4-7, 9-11) have proven the utility of atomic absorption spectrophotometry (AAS) in the clinical laboratory. However, until very recently there has been very little if any published information dealing with normal serum calcium values by atomic absorption spectrophotometry (11). The primary purp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 11 شماره
صفحات -
تاریخ انتشار 1987