Influence of Different Shellfish Matrices on the Separation of PSP Toxins Using a Postcolumn Oxidation Liquid Chromatography Method
نویسندگان
چکیده
The separation of PSP toxins using liquid chromatography with a post-column oxidation fluorescence detection method was performed with different matrices. The separation of PSP toxins depends on several factors, and it is crucial to take into account the presence of interfering matrix peaks to produce a good separation. The matrix peaks are not always the same, which is a significant issue when it comes to producing good, reliable results regarding resolution and toxicity information. Different real shellfish matrices (mussel, scallop, clam and oyster) were studied, and it was seen that the interference is not the same for each individual matrix. It also depends on the species, sampling location and the date of collection. It was proposed that separation should be accomplished taking into account the type of matrix, as well as the concentration of heptane sulfonate in both solvents, since the mobile phase varies regarding the matrix. Scallop and oyster matrices needed a decrease in the concentration of heptane sulfonate to separate GTX4 from matrix peaks, as well as dcGTX3 for oysters, with a concentration of 6.5 mM for solvent A and 6.25 mM for solvent B. For mussel and clam matrices, interfering peaks are not as large as they are in the other group, and the heptane sulfonate concentration was 8.25 mM for both solvents. Also, for scallops and oysters, matrix interferences depend not only on the sampling site but also on the date of collection as well as the species; for mussels and clams, differences are noted only when the sampling site varies.
منابع مشابه
Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish
In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1-4) and the N-sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v/v) with ...
متن کاملComparison of biosensor platforms for surface plasmon resonance based detection of paralytic shellfish toxins.
Paralytic shellfish poisoning (PSP) toxins are produced by certain marine dinoflagellates and may accumulate in bivalve molluscs through filter feeding. The Mouse Bioassay (MBA) is the internationally recognised reference method of analysis, but it is prone to technical difficulties and regarded with increasing disapproval due to ethical reasons. As such, alternative methods are required. A rap...
متن کاملOptimization of Sample Preparation for the Identification and Quantification of Saxitoxin in Proficiency Test Mussel Sample using Liquid Chromatography-Tandem Mass Spectrometry
Saxitoxin (STX) and some selected paralytic shellfish poisoning (PSP) analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test...
متن کاملDetermination of Gonyautoxin-4 in Echinoderms and Gastropod Matrices by Conversion to Neosaxitoxin Using 2-Mercaptoethanol and Post-Column Oxidation Liquid Chromatography with Fluorescence Detection
Paralytic Shellfish Toxin blooms are common worldwide, which makes their monitoring crucial in the prevention of poisoning incidents. These toxins can be monitored by a variety of techniques, including mouse bioassay, receptor binding assay, and liquid chromatography with either mass spectrometric or pre- or post-column fluorescence detection. The post-column oxidation liquid chromatography wit...
متن کاملResults of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies
A saxitoxin (STX) proficiency test (PT) was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox) project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories' capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel materi...
متن کامل