Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation.
نویسندگان
چکیده
BACKGROUND The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers. METHODS Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compared in a model of adult mechanical ventilation, with heated/humidified and non-humidified ventilator circuits. Albuterol sulfate was aerosolized at 3 circuit positions: (1) between the endotracheal tube and the Y-piece; (2) 15 cm from Y-piece; and (3) 15 cm from the ventilator, with each device (n = 3) using adult settings (tidal volume 500 mL, ramp flow pattern, 15 breaths/min, peak inspiratory flow 60 L/min, and PEEP 5 cm H(2)O). The drug deposited on an absolute filter distal to an 8.0-mm inner-diameter endotracheal tube was eluted and analyzed via spectrophotometry (276 nm), and is reported as mean +/- SD percent of total nominal or emitted dose. RESULTS The vibrating-mesh nebulizer, ultrasonic nebulizer, and pMDI with spacer were most efficient in position 2 with both non-humidified (30.2 +/- 1.0%, 24.7 +/- 4.4%, and 27.8 +/- 3.3%, respectively) and heated/humidified circuits (16.8 +/- 2.6%, 16.5 +/- 4.3%, and 17 +/- 1.0%, respectively). In contrast, the jet nebulizer was most efficient in position 3 under both non-humidified (14.7 +/- 1.5%) and heated/humidified (6.0 +/- 0.1%) conditions. In positions 2 and 3, all devices delivered approximately 2-fold more drug under non-humidified than under heated/humidified conditions (P < .01). At position 1 only the pMDI delivered substantially more drug than with the non-humidified circuit. CONCLUSION During mechanical ventilation the optimal drug delivery efficiency depends on the aerosol generator, the ventilator circuit, and the aerosol generator position.
منابع مشابه
Comparison of Nasal Non-invasive Ventilation Methods in Preterm Neonates with Respiratory Distress Syndrome
Background: Humidified heated high flow nasal cannula (HHHFNC), nasal continuous positive airway pressure (NCPAP), and nasal intermittent positive pressure ventilation (NIPPV) are three nasal non-invasive ventilation methods. The purpose of this study was to compare these three methods in decreasing intubation and mechanical ventilation rate in preterm neonates with respiratory distress syndrom...
متن کاملReconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors.
We attempted to resolve the discrepancies in reported data on aerosol deposition from a chlorofluorocarbon (CFC)-propelled metered-dose inhaler (MDI) during mechanical ventilation, obtained by in vivo and in vitro methodologies. Albuterol delivery to the lower respiratory tract was decreased in a humidified versus a dry circuit (16.2 versus 30.4%, respectively; p < 0.01). In 10 mechanically ven...
متن کاملHeated Humidified High Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure as Primary Mode of Respiratory Support for Respiratory Distress in Preterm Infants.
OBJECTIVE To compare the outcomes of preterm infants with respiratory distress initiated on either Heated Humidified High Flow Nasal Cannula or Nasal Continuous Positive Airway Pressure as a primary mode of respiratory support. STUDY DESIGN Prospective observational cohort study. SETTING Tertiary care level III neonatal intensive care unit. PARTICIPANTS 88 preterm infants between 28 to 34...
متن کاملHeated Humidified High-Flow Nasal Cannula Versus Nasal Continuous Positive Airway Pressure for the Facilitation of Extubation in Preterm Neonates with Respiratory Distress
Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity as an alternative to nasal continuous positive airway pressure (nCPAP) therapy in the management of preterm neonates with respiratory distress due to ease of administration and patient comfort. However, limited evidence is available addressing its risks and benefits. To study the efficacy and safety of HHHFNC i...
متن کاملAerosol delivery during mechanical ventilation: from basic techniques to new devices.
Pressurized metered-dose inhalers (pMDIs) and nebulizers are routinely employed for aerosol delivery in mechanically ventilated patients. A significant proportion of the aerosol deposits in the ventilator circuit and artificial airway, thereby reducing the inhaled drug mass. Factors influencing aerosol delivery during mechanical ventilation differ from those in spontaneously breathing patients....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 55 7 شماره
صفحات -
تاریخ انتشار 2010