Optimal in vitro realization of pulsatile coronary artery flow waveforms using closed-loop feedback algorithms with multiple flow control devices

نویسندگان

  • Serdar YILMAZ
  • Onur TOKER
  • Nurullah ARSLAN
  • Herman SEDEF
چکیده

In this paper, we study optimal in vitro realization of pulsatile coronary artery flows using newly proposed closed-loop feedback algorithms with a clearly defined mathematical performance objective, and we compare several flow control device technologies in terms of their ability to generate pulsatile flow signals as accurately as possible. In the literature, there are several published results for in vitro pulsatile flow realization systems. However, most of the proposed systems operate in an open-loop setting and use a single flow control device, and their performance is assessed mostly by graphical means without a clearly defined mathematical performance objective. Furthermore, some authors take the average of the generated pulsatile flow and compare it with the desired flow signal for performance analysis. What makes this work different from other published results in this area are: 1) the use of closed-loop feedback control rather than an open-loop approach; 2) the use of a clearly defined mathematical performance objective rather than a visual comparison of the generated and desired flow graphs; 3) newly proposed control algorithms with demonstrated performance improvements as compared to the published ones; 4) the use of multiple flow control devices, their performance comparisons, and optimal technology selection; and 5) not taking the average of the generated flow signal over several cycles for performance assessment, but instead using the nonaveraged actual flow signal and comparing it with the desired one. In pulsatile flow realization, what is important is the L1 distance between the desired and delayed versions of the generated flows in the steady state regime, and the defined mathematical performance objective is completely based on this point. Furthermore, there are 3 different flow control devices that are comparatively analyzed: the pneumatic valve, the servo valve, and an AC inverter driving a centrifugal pump. Finally, there are several new closed-loop control algorithms proposed in this paper: P-Σ , P-Σ predictive, PΣ look ahead, and model-based nonlinear feed-forward, feed-forward predictive, and feed-forward look-ahead control. Each algorithm’s performance is compared with that of PID performance as a benchmark test to ∗Corresponding author: Department of Electrical and Electronics Engineering, Fatih University, İstanbul-TURKEY

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Real-Time Programmable Pulsatile Flow Pump for In Vitro Cardiovascular Experimentation.

Benchtop in vitro experiments are valuable tools for investigating the cardiovascular system and testing medical devices. Accurate reproduction of the physiologic flow waveforms at various anatomic locations is an important component of these experimental methods. This study discusses the design, construction, and testing of a low-cost and fully programmable pulsatile flow pump capable of conti...

متن کامل

Fluidic Oscillators’ Applications, Structures and Mechanisms – A Review

Enhancement of heat and mass transfer and decrease of energy dissipation are great necessities of the evolution of fluid flow devices. Utilizing oscillatory or pulsatile fluid flow for periodic disturbing of velocity and thermal boundary layers is one of the methods with exciting results. Passive methods of generating oscillatory flow are preferred to active methods because of simplicity, no ne...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

Control of Heart Assist Devices

In this paper, we discuss several control techniques for Ventricular Assist Devices (VADs) and describe a hierarchical control structure that can be used to regulate the operation of a turbo-hydrodynamic VAD. Early assist devices were pulsatile, and control usually focused on regulating flow, atrial and/or arterial pressures. In recent years, non-pulsatile turbo-hydronamic devices have been int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012