We modify the time-dependent electric potential of the Paul trap from a sinusoidal waveform to a square waveform. Exact quantum motion and Berry’s phase of an electron in the modified Paul trap are found in an analytically closed form. We consider a scheme to detect the Berry’s phase by a BohmAharonov type interference experiment, and point out a critical property which renders it practicable. 03.65.Bz Typeset using REVTEX ∗Electronic address: [email protected] †Electronic address: [email protected] 1
منابع مشابه
جداسازی یون توسط دام چهار قطبی در حضور نیروی میراکننده
Dynamical behavior of particles in a Paul trap has been investigated by solving the set of differential equations considering the effect of damping force. Positions of the trapped ions as a function of time, ion trajectories and the phase space curves in the first stability region have been obtained in the presence of the damping force. The region of stability for r and z components as well as ...
متن کاملمحاسبه نواحی سوم, چهارم و پنجم پایداری در دام پاول
The behavior of ions in a Paul trap has been investigated using numerical solution of the set of Mathieus differential equations. Afterwards, the trajectories of two typical ions such as H+ and 208Pb+ in the trap have been obtained using the fourth-order Runge-Kutta method. For specific dimensions of a Paul trap and a given frequency, the stability regions for separation of H+ and 2H+ ions hav...
متن کاملBerry phase for a particle in an infinite spherical potential well with moving wall
In this paper we calculate the Berry phase for a wave function of a particle in an infinite spherical potential well with adiabatically varying. In order to do this, we need the solutions of the corresponding Schrödinger equation with a time dependent Hamiltonian. Here, we obtain these solutions for the first time. In addition, we calculate the Berry phase in one dimensional case for an infinit...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کامل