Thermoconvectional phenomena induced by vibrations in supercritical SF6 under weightlessness.

نویسندگان

  • Y Garrabos
  • D Beysens
  • C Lecoutre
  • A Dejoan
  • V Polezhaev
  • V Emelianov
چکیده

The effect of a linear harmonic vibration on heat propagation is investigated in near-critical SF6 under weightlessness conditions in space. Heat was issued from a pointlike source (thermistor), a situation representative of an industrial use of pressurized supercritical fluid storage. Two kinds of vibrations were used, large amplitude (64 mm) at 0.2 Hz and low amplitude (0.8 mm) at 1.6 Hz, with temperatures from 5 K to 20 mK from the critical temperature. The vibrations are seen to strongly affect the evolution and shape of the hot boundary layer (HBL), the heat exchange between the heat source and the fluid, and the bulk thermalization process by the adiabatic piston-effect process. The HBL is initially convected as symmetrical plumes over a distance that only depends on the vibration velocity and which corresponds to a Rayleigh-Bénard-like instability where the vibration acceleration acts as the earth gravity. Then the extremities of the plumes are convected perpendicularly to the direction of oscillation as two "pancakes," a process encountered in the vibrational Rayleigh-Bénard instability. When the vibration velocity is small, only one pancake centered at the hot source is observed. Temperature evolutions of the hot source and the fluid are studied in different locations. Convection flows and adiabatic piston effect compete to determine the thermal dynamics, with the latter being the most efficient near the critical point. The experimental results are compared with a two-dimensional numerical simulation that highlights the similarities and differences between the very compressible van der Waals gas and an ideal gas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure

Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...

متن کامل

Performance of Shred Tire Mixed with Railway Subgrade in Reduction of Train Induced Vibrations

In this study, the performance of shred tire mixed with railway subgrade is evaluated to reduce environmental vibrations caused by trains’ passage. Since incorporating the Shred Tire seeds in soil affects on its shear strength and deformability parameters so, the first stage of the study was allocated to conducting a series of laboratory tests such as the unconfined compression test, and CBR an...

متن کامل

Response Spectra of Structures under Subway Induced Vibrations

Passing underground trains induce vibrations transmitted to the ground surface and the nearby structures. Ordinarily, these vibrations do not result in structural damage but can harm nonstructural elements and disturb the occupants. These effects are more pronounced when evaluating buildings like hospitals, laboratories, museums, etc., and their assessment is an important design need. To respon...

متن کامل

Objects Mental Rotation under 7 Days Simulated Weightlessness Condition: An ERP Study

During the spaceflight under weightlessness condition, human's brain function may be affected by the changes of physiological effects along with the distribution of blood and body fluids to the head. This variation of brain function will influence the performance of astronauts and therefore create possible harm to flight safety. This study employs 20 male subjects in a 7-day-6° head-down tilted...

متن کامل

Induced Overvoltages on the SF6 Substation Enclosure Caused by Switching

Abstract – This paper investigates overvoltages on the SF6 substation enclosure caused by the switching operation of the interrupter. The paper analyzes the amplitude and the overvoltage duration on the substation enclosure. Switching overvoltages take part in the everyday drive of HV substations and constitute an undesired phenomenon that may often, beside transient disturbances, lead to undes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 75 5 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2007