Phase-dependent sensitivity to heterochromatic flicker.

نویسندگان

  • D T Lindsey
  • J Pokorny
  • V C Smith
چکیده

We measured modulation sensitivity to a pair of equally luminous sinusoidally modulated lights (568 and 630 nm) as a function of their relative phase. Measurements were made for 2, 3, 6, and 12 Hz at a retinal illuminance of 100 Td. The data indicated that two processes were active and their outputs combined by a vector summation rule. There was a phase shift of -18 degrees to -20 degrees (630 nm leads 568 nm) at 6 Hz, no phase shift at 12 Hz, an equivocal shift at 2 Hz, and an indeterminate shift at 3 Hz. At frequencies where a phase shift was observed, our analysis indicated that the phase shift affected sensitivities measured at all relative phase settings. These results are inconsistent with models postulating equal contributions of long-wavelength- and middle-wavelength-receptors to centers and surrounds of processes responsible for the detection of luminance flicker.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of chromatic adaptation on phase-dependent sensitivity to heterochromatic flicker.

Temporal modulation sensitivity was measured as a function of the relative phase of two equiluminous chromatic sources (564 and 625 nm) for temporal frequencies from 6 to 20 Hz. The difference between 180 degrees and the phase of least sensitivity was computed as the measured phase shift. A 2 degree test field was superimposed upon 8 degrees chromatic adapting fields with luminances from 100 to...

متن کامل

Amplitude and phase of responses of macaque retinal ganglion cells to flickering stimuli.

1. We have measured responses of macaque retinal ganglion cells to a uniform flickering field, with variation in luminance, chromaticity or both (heterochromatic flicker). 2. With heterochromatic flicker, as the luminance ratio of the flicker components was varied, phasic ganglion cell activity went through a minimum and an abrupt phase change close to equal luminance. Tonic ganglion cell respo...

متن کامل

Heterochromatic modulation photometry.

Heterochromatic modulation photometry is a method for obtaining equiluminance for a pair of heterochromatic lights presented in temporal alternation. A series of fixed standard luminance/test luminance ratios are presented, and at each ratio the modulation depth of the pair is reduced in tandem until the observer reports that flicker disappears. The data can be described by a luminance contrast...

متن کامل

Effects of temporal frequency on phase-dependent sensitivity to heterochromatic flicker.

Modulation sensitivity was measured as a function of the relative phase of two equiluminous chromatic sources (564 and 625 nm) for temporal frequencies ranging from 1 to 40 Hz. Measurements were made at a retinal illuminance of 900 Td, with a 2 degree field metameric to approximately 600 nm. For most frequencies, the phase of least sensitivity was other than 180 degrees, indicating the existenc...

متن کامل

Luminous-efficiency functions for point sources.

Luminous-efficiency functions for small fields were measured with flicker photometry and heterochromatic brightness-matching methods for the same two subjects. For the larger stimuli (22.9 and 11.5'), the luminous-efficiency functions differed between the two methods. Those obtained by flicker photometry showed a simple narrow shape, whereas those obtained by heterochromatic brightness matching...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics and image science

دوره 3 7  شماره 

صفحات  -

تاریخ انتشار 1986