Comparison of Efficacy and Safety between Transconjunctival 23-Gauge and Conventional 20-Gauge Vitrectomy Systems in Macular Surgery

نویسندگان

  • Tugba Goncu
  • Gokhan Gurelik
  • Berati Hasanreisoglu
چکیده

PURPOSE To compare the efficacy and safety of 23-gauge transconjunctival vitrectomy with the conventional 20-gauge method in idiopathic epiretinal membrane and macular hole surgery. METHODS Sixty-one consecutive patients undergoing vitrectomy for idiopathic epiretinal membrane and macular hole were recruited to either 20- or 23-gauge vitrectomy groups and prospectively evaluated. Surgical success rates, operating time, surgery-related complications, long-term visual outcomes, and postoperative ocular surface problems are compared in the two groups. RESULTS There were 31 eyes in the 20-gauge group and 33 eyes in the 23-gauge group. The macular hole closure rate after the first surgery was 83% and 90.9% in the 20-gauge and 23-gauge groups, respectively, with no significant difference between groups (p = 0.59). The success rate for idiopathic epiretinal membranes cases was 100% in both groups. There was no statistically significant difference between overall surgical times (p = 0.90). None of the patients in either group experienced postoperative complications of severe postoperative hypotony, vitreous hemorrhage or endophthalmitis, except one eye in the 20-gauge group, which was found to have retinal detachment. In both groups, statistically significant improvement in visual acuity was achieved 1-month postoperatively (p = 0.002) and thereafter at all postoperative visits (p < 0.05). The mean ocular surface scores were significantly lower in the 23-gauge group at all postoperative visits compared with the 20-gauge group scores (p = 0.001). CONCLUSIONS Transconjunctival 23-gauge vitrectomy appears to be as effective and safe as conventional 20-gauge vitrectomy in idiopathic epiretinal membrane and macular hole surgeries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intraoperative Retinal Break Formation during Standard 20-Gauge and 23-Gauge Sutureless Vitrectomy Systems

Purpose: The aim of this study was to compare the rate and location of intraoperatively induced retinal breaks between two techniques of standard 20-gauge vitrectomy and transconjunctival 23-gauge using trocar/cannula Methods: In this prospective comparative case series patients having attached retina before surgery who were operated for different vitreoretinal or macular conditions by standard...

متن کامل

The Safety and Efficacy of Transconjunctival Sutureless 23-gauge Vitrectomy

PURPOSE To evaluate the efficacy and safety of vitreoretinal surgery using a 23-gauge transconjunctival sutureless vitrectomy (TSV) system for various vitreoretinal diseases. METHODS A retrospective, consecutive, interventional case series was performed for 40 eyes of 40 patients. The patients underwent vitreoretinal procedures using the 23-gauge TSV system, including idiopathic epiretinal me...

متن کامل

Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy

BACKGROUND To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS Retrospective case notes review of two consecutive series of patients who had primary pars plana vitrectomy for complications of proliferative diabetic r...

متن کامل

Intraoperative retinal tear formation and postoperative rhegmatogenous retinal detachment in transconjunctival cannulated vitrectomy systems compared with the standard 20-gauge system.

OBJECTIVE To compare 20-gauge standard pars plana vitrectomy (PPV) with transconjunctival cannulated PPV in the development of intraoperative retinal breaks and postoperative rhegmatogenous retinal detachments (RRDs) in a large series of patients undergoing PPV for macular pucker or macular hole. METHODS This study was conducted at an academic tertiary care vitreoretinal practice in Milwaukee...

متن کامل

Advances in Vitreo-retinal Surgery: 23-gauge Sutureless Pars Plana Vitrectomy

Pars plana vitrectomy is one of the most common surgical procedures performed for the treatment of various vitreo-retinal diseases such as retinal detachment, vitreous haemorrhage, proliferative diabetic retinopathy, epiretinal membrane and macular hole. Traditionally, most vitrectomy surgical systems utilise the 20-gauge instruments pars plana vitrectomy includes multiple incisions including p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2012