Object. The implantation of interbody fusion cages allows for the restoration of disc height and the enlargement of the neuroforaminal space. The purpose of this study was to compare the extent of subsidence occurring after conventional cage placement compared to a novel wider cage placement technique. Methods. This study is a retrospective evaluation of radiographs of patients who underwent stand-alone single level anterior lumbar interbody fusion with lordotic titanium cages and rhBMP-2. Fifty-three patients were evaluated: 39 patients had wide cage placement (6 mm interdevice distance) and 14 had narrow cage placement (2 mm interdevice distance). Anterior and posterior intervertebral disc space heights were measured post-operatively and at follow-up imaging. Results. The decrease in anterior intervertebral disc space height was 2.05 mm versus 3.92 mm (P < .005) and 1.08 mm versus 3.06 mm in posterior disc space height for the wide cage placement and the narrow cage placement respectively. The proportion of patients with subsidence greater than 2 mm was 41.0% in the wide cage patients and 85.7% for the narrow cage patients (P < .005). Conclusions. The wider cage placement significantly reduced the amount of subsidence while allowing for a greater exposed surface area for interbody fusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY

The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...

متن کامل

Failure of a Carbon Fiber–Reinforced Polymer Implant Used for Transforaminal Lumbar Interbody Fusion

Lumbar interbody fusion is a common procedure owing to the high prevalence of degenerative spinal disorders. During such procedures, carbon fiber-reinforced polymer (CFRP) cages are frequently utilized to fill the void created between adjacent vertebral bodies, to provide mechanical stability, and to carry graft material. Failure of such implants can lead to significant morbidity. We discuss th...

متن کامل

Role of Minimally Invasive Spine Surgery in Adults with Degenerative Lumbar Scoliosis: A Narrative Review

Background and Aim: Degenerative lumbar scoliosis is a spinal deformity resulting from advanced disc degeneration and facet arthropathy. Given the inconclusive available literature and lack of high-quality data supporting the role of minimally invasive surgical management of degenerative lumbar scoliosis, this review intends to highlight and compare the various viable minimally invasive surgica...

متن کامل

Biomechanical Analysis of Anterior Spinal Instrumentation Constructs for Lumbar Fusions

Corrective surgery for scoliosis with anterior instrumentation can be accomplished with different constructs: single rod, single rod with interbody cages and dual rods. These varying constructs are most often used in the lumbar spine to generate a fusion mass while retaining the natural lordosis of the lumbar region (Sweet, 1999). In a pediatric population or in smaller adults, two screws canno...

متن کامل

Flexibility and fatigue evaluation of oblique as compared with anterior lumbar interbody cages with integrated endplate fixation.

OBJECTIVE This study was undertaken to quantify the in vitro range of motion (ROM) of oblique as compared with anterior lumbar interbody devices, pullout resistance, and subsidence in fatigue. METHODS Anterior and oblique cages with integrated plate fixation (IPF) were tested using lumbar motion segments. Flexibility tests were conducted on the intact segments, cage, cage + IPF, and cage + IP...