Repeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes

نویسندگان

  • Carmen Lopez de la Fuente
  • Ana Sanchez-Cano
  • Francisco Segura
  • Lorena Fuentes-Broto
  • Isabel Pinilla
چکیده

PURPOSE To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination. METHODS Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calculating intraclass correlation coefficient (ICC), and coefficient of variation (COV). RESULTS Correlation among repeated measurements showed almost perfect reliability (ICC>0.81) for all parameters except thinnest central corneal thickness (CCT) (0.78), corneal thickness average out (0.79), and posterior axial curvature average out (0.60). Repeatability was excellent (COV<10%) for all parameters except anterior chamber volume and, superior iridocorneal angle and eccentricities. In these last three parameters, repeatability limits were excessively high compared to the mean. CONCLUSIONS GDSA in healthy young persons had an almost perfect correlation in measuring anatomic, axial, instantaneous, and refractive parameters with greater variability for peripheral terms. Repeatability of anatomical parameters like pachymetry, anterior chamber, or iridocorneal angle and eccentricity were limited. In healthy young persons, the other evaluated parameters had very good repeatability and their limits of agreement showed excellent clinical results for this device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer

OBJECTIVES To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal high...

متن کامل

Comparative Evaluation of Elevation, Keratometric, Pachymetric and Wavefront Parameters in Normal Eyes, Subclinical Keratoconus and Keratoconus with a Dual Scheimpflug Analyzer

Purpose: To compare the corneal parameters in normal corneas, forme fruste keratoconus (FFKC) and keratoconus measured with a dual Scheimpflug analyzer. Materials and methods: A total of 372 eyes of 197 patients were prospectively enrolled in the study and divided into three groups: 148 eyes of 102 patients with keratoconus, 47 contralateral topographically normal eyes of clinically evident ker...

متن کامل

Comparison of Anterior Segment Measurements Obtained by Three Different Devices in Healthy Eyes

PURPOSE To assess the normal values and the repeatability of the Galilei Dual Scheimpflug Analyzer (GDSA), the biometer IOL Master, and the autokerato/refractometer WAM 5500 in anterior segment examinations. METHODS Eighty-eight eyes from 88 healthy volunteers were prospectively and consecutively recruited. The repeatability was assessed, calculating the intraclass correlation coefficient (IC...

متن کامل

Comparison of Central Corneal Thickness Measurement Using Non-Contact and Contact Pachymetry Devices in Normal Eyes

Materials and Methods: This prospective, cross sectional comparative study evaluated 30 healthy subjects fulfilling the inclusion criteria reporting in AFIO Rawalpindi. CCT was measured in both eyes of subjects using noncontact specular microscope, Dual Scheimpflug analyzer and contact ultrasound pachymeter by a single investigator at the same time of the day. Pearson’s correlation coefficient ...

متن کامل

Comparison of Anterior Corneal Curvature Measurements Using a Galilei Dual Scheimpflug Analyzer and Topcon Auto Kerato-Refractometer

Purpose. To compare anterior corneal keratometry (K) measurements taken by a dual Scheimpflug analyzer and an auto kerato-refractometer. Methods. Sixty-four normal eyes underwent keratometric measurements with both devices. The repeatability of the auto kerato-refractometer measurements was assessed by calculating the coefficient of variation (COV). The interdevice agreement was evaluated using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014