Reproducibility of myocardial velocity and deformation imaging in term and preterm infants.

نویسندگان

  • Suchita Joshi
  • Julie M Edwards
  • Dirk G Wilson
  • Joon K Wong
  • Sailesh Kotecha
  • Alan G Fraser
چکیده

AIMS Myocardial velocity imaging has been validated in adults for assessment of ventricular function and indirect indices of pulmonary arterial pressure. To establish whether it could also be used in infants, we investigated the reproducibility of myocardial velocities and deformation indices in term and preterm neonates. METHODS AND RESULTS Myocardial velocity loops acquired from 16 infants were analysed by four observers for inter-observer variability, and re-analysed after 6 months by one observer for intra-observer variability. For myocardial velocities, the coefficients of variation (CVs) for the left ventricle (LV) were 10-11 (intra-observer) and 14-20% (inter-observer) and for the right ventricle (RV) 15-19 and 18-24%, respectively. Reproducibility for annular displacements was <13% (intra-observer) and <18% (inter-observer). CVs for LV strain were 14-17 (intra-observer) and 36-43% (inter-observer) and for RV 19-24 and 25-37%. CVs for isovolumic acceleration were in general >40%. In comparison, the CVs for blood pool indices were 3-15%. CONCLUSION Intra-observer reproducibility for myocardial velocity and deformation indices in neonates is adequate for these parameters to be used in clinical research. Inter-observer reproducibility is sub-optimal suggesting that these measurements should be used in clinical practice with caution. Myocardial acceleration, a marker of contractile function, was poorly reproducible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of myocardial deformation imaging in term and preterm infants.

AIMS Myocardial deformation imaging is now used to assess regional ventricular function in infants but their small size presents particular technical challenges. We therefore investigated the determinants of reproducibility of myocardial longitudinal strain (ε) in term and preterm infants, in order to determine optimal technical settings. METHODS AND RESULTS Repeated longitudinal ε measuremen...

متن کامل

The Effect of Early Subcutaneous Administration of Erythropoietin on Hematopoiesis and Weight Gain Velocity in Preterm Infants

Abstract Introduction Anemia in preterm infants is identified as hemoglobin lower than 7-10g/dl around 1-3 months after birth. The aim of this study was to evaluate the effect of early subcutaneous administration of erythropoietin on hematopoiesis and weight gain velocity in preterm infants. Materials and Methods The present study was clinical trial carried out on 42 preterm infants. Those ...

متن کامل

Progression of Right Ventricular Systolic Dysfunction Detected by Myocardial Deformation Imaging in Asymptomatic Preterm Children

Background To detect progression of right ventricular (RV) systolic dysfunction (RVSD) in asymptomatic preterm children from infancy to 24-month corrected age, using velocity vector imaging (VVI). Methods Retrospective study comparing sequential RV longitudinal peak systolic strain (LPSS) from 24 children born at < 33 weeks of gestational age and 10 term infants recruited as controls, obtaine...

متن کامل

Comparison of Vitamin D Level in Preterm and Term Infant–Mother Pairs: A Brief Study

Background: Recent studies have demonstrated the high prevalence of vitamin D deficiency in the general population. Pregnancy and preterm delivery are known as risk factors for vitamin D deficiency. Consequently, vitamin D level in women with preterm deliveries might vary from those with term pregnancies. In this study, we aimed to compare vitamin D level in term and preterm infant–mother pairs...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2010