Heat Transfer to Laminar Flow over a Double Backward-Facing Step
نویسندگان
چکیده
Heat transfer and laminar air flow over a double backward-facing step numerically studied in this paper. The simulations was performed by using ANSYS ICEM for meshing process and using ANSYS fluent 14 (CFD) for solving. The k-ɛ standard model adopted with Reynolds number varied between 98.5 to 512 and three step height at constant heat flux (q=2000 W/m2). The top of wall and bottom of upstream are insulated with bottom of downstream is heated. The results show increase in Nusselt number with increases of Reynolds number for all cases and the maximum of Nusselt number happens at the first step in compared to the second step. Due to increase of cross section area of downstream to generate sudden expansion then Nusselt number decrease but the profile of Nusselt number keep same trend for all cases where increase after the first and second steps. Recirculation region after the first and second steps are denoted by contour of streamline velocity. The higher augmentation of heat transfer rate observed for case 1 at Reynolds number of 512 and heat flux q=2000 W/m. Keywords—Laminar flow, Double backward, Separation flow, Recirculation flow.
منابع مشابه
Three Dimensional Laminar Convection Flow of Radiating Gas over a Backward Facing Step in a Duct
In this study, three-dimensional simulations are presented for laminar forced convection flow of a radiating gas over a backward-facing step in rectangular duct. The fluid is treated as a gray, absorbing, emitting and scattering medium. The three-dimensional Cartesian coordinate system is used to solve the governing equations which are conservations of mass, momentum and energy. These equations...
متن کاملEnhancement of Heat Transfer over a Double Forward Facing Step with Square Obstacle through Taguchi’s Optimization Technique
In this paper, the heat transfer to the fluid, passing through the double forward facing step (FFS) channel with square obstacle is enhanced by Taguchi’s S/N ratio analysis. Flow through the forward facing step channel has a wide range of applications in thermal systems due to its flow separation and subsequent reattachment, which in turn enhances the heat transfer. Flow separation and reattach...
متن کاملNumerical Study of Heat Transfer and Laminar Flow over a Backward Facing Step with and without Obstacle
Heat transfer and laminar fluid flow over backward facing step with and without obstacle numerically studied in this paper. The finite volume method adopted to solve continuity, momentum and energy equations in two dimensions. Backward facing step without obstacle and with different dimension of obstacle were presented. The step height and expansion ratio of channel were 4.8mm and 2 respectivel...
متن کاملIvestigation of Entropy Generation in 3-D Laminar Forced Convection Flow over a Backward Facing Step with Bleeding
A numerical investigation of entropy generation in laminar forced convection of gas flow over a backward facing step in a horizontal duct under bleeding condition is presented. For calculation of entropy generation from the second law of thermodynamics in a forced convection flow, the velocity and temperature distributions are primary needed. For this purpose, the three-dimensional Cartesian co...
متن کاملPrediction of Fluid Flow and Heat Transfer Characteristics Behind a Single Backward-Facing Step
Numerical solutions based on standard finite volume method are presented for the study of heat transfer and fluid dynamic characteristics in turbulent flows behind a single sided backward-facing step. The calculation of the differential equations is performed using SIMPLE algorithm. For the turbulent quantities standard K-model is used. Predicted mean velocity profiles and reattachment lengths ...
متن کامل