Microbial contamination of suction tubes attached to suction instruments and preventive methods.

نویسندگان

  • Katsuhiro Yorioka
  • Shigeharu Oie
  • Akira Kamiya
چکیده

We investigated the microbial contamination of suction tubes attached to wall-type suction instruments. Microbial contamination of suction tubes used for endoscopy or sputum suction in hospital wards was examined before and after their disinfection. In addition, disinfection and washing methods for suction tubes were evaluated. Suction tubes (n=33) before disinfection were contaminated with 10(2)-10(8) colony-forming units (cfu)/tube. The main contaminants were Pseudomonas aeruginosa, Acinetobacter baumannii, and Stenotrophomonas maltophilia. The suction tubes were disinfected with sodium hypochlorite (n=11) or hot water (n=11), or by an automatic tube cleaner (n=11). After 2-h immersion in 0.1% (1,000 ppm) sodium hypochlorite, 10(3)-10(7) cfu/tube of bacteria were detected in all 11 tubes examined. After washing in hot running water (65 degrees C), 10(3)-10(7) cfu/tube were detected in 3 of the 11 examined tubes. The bacteria detected in the suction tubes after disinfection with sodium hypochlorite or hot water were P. aeruginosa, A. baumannii, and S. maltophilia. On the other hand, after washing with warm water (40 degrees C) using the automatic tube cleaner, contamination was found to be <20 cfu/tube (lower detection limit, 20 cfu/tube) in all 11 tubes examined. These results suggest the usefulness of washing with automatic tube cleaners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbial Contamination of Suction Tubes Attached to Suction Instrument and Its Preventive Methods

We investigated the microbial contamination of suction tubes attached to wall-type suction instrument. Microbial contamination of suction tubes used for endoscopy or sputum suction in wards was examined before and after their disinfection. In addition, disinfection and washing methods for suction tubes were evaluated. Suction tubes (N=33) before disinfection were contaminated with 102-108 colon...

متن کامل

Comparison of the prevalence of pericardial effusion and cardiac tamponade after cardiac surgery with and without chest tube suction in patients referred to Chamran hospital, Isfahan

Background: Pericardial effusion is one of the most important complications of cardiac surgeries. Administration of a low-power suction to the mediastinal or pleural chest tube of patients helps better and constant drainage of pericardial or pleural secretions after surgeries. This technique might change the secretion and discharges of patients and might change the outcomes of surgeries. Metho...

متن کامل

Evaluation of Bacterial Contamination in a Clinical Environment

BACKGROUND Although the contamination of the dental environment and personnel through aerosol contamination is a definite source of cross contamination; there is little data on the microbial involvement of the dental environment. MATERIALS AND METHODS A total of 100 samples were taken from various inanimate surfaces in the clinical dental setting were collected aseptically by rotating sterile...

متن کامل

Comparison of the Effects of Open and Closed Endotracheal Suction on Cardiovascular and Ventilation Parameters for Patients Undergoing Mechanical Ventilation

Background and Objectives: Suction is a necessary and common method which aids in the release of secretion from the respiratory system for the patients who have undergone mechanical ventilation. One of the most common complications of suction is hypoxemia which causes dysrhythmia and death. The purpose of this study was to determine the effects of open and closed-endotracheal suction on cardiov...

متن کامل

Esophageal food impaction: a homemade suction tube attached to esophagogastroduodenoscopy for food bolus removal.

The most common esophageal foreign body in adults is impacted food bolus. Polypectomy snares, Dormia baskets, retrieval nets, rat-tooth forceps, alligator forceps or polyp graspers are usually used to remove it. Here, we report the case of a 78-year-old woman whose esophagogastroduodenoscopy (EGD) showed a firm goose liver impacted tightly in the lower esophagus; all of the above-mentioned retr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of infectious diseases

دوره 63 2  شماره 

صفحات  -

تاریخ انتشار 2010