Air-Leak Effects on Ear-Canal Acoustic Absorbance
نویسندگان
چکیده
OBJECTIVE Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. DESIGN Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1-0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. RESULTS The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1-0.2 and 0.2-0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables exhibited consistent dependence on air-leak size. Low-frequency admittance phase and CV/PV decreased, while low-frequency absorbance and the air-leak resonance frequency increased. CONCLUSION The effect of air leaks can be significant when their equivalent diameter exceeds 0.01 in. The observed effects were greatest at low frequencies where air leaks caused absorbance to increase. Recommended criteria for detecting air leaks include the following: when the frequency range of interest extends as low as 0.1 kHz, low-frequency absorbance should be ≤0.20 and low-frequency admittance phase ≥61 degrees. For frequency ranges as low as 0.2 kHz, low-frequency absorbance should be ≤0.29 and low-frequency admittance phase ≥44 degrees.
منابع مشابه
An unusual site of a CSF leak following resection of a retrosigmoid acoustic neuroma.
Cerebrospinal fluid (CSF) leaks may occur after acoustic neuroma resection. These leaks are usually the result of an iatrogenic injury during removal. The retrosigmoid approach is commonly associated with leaks that occur through the lateral end of the internal auditory canal, through the perilabyrinthine cells extending to the region of the internal auditory canal, or through the retrosigmoid ...
متن کاملAcoustic Immittance, Absorbance, and Reflectance in the Human Ear Canal.
Ear canal measurements of acoustic immittance (a term that groups impedance and its inverse, admittance) and the related quantities of acoustic reflectance and power absorbance have been used to assess auditory function and aid in the differential diagnosis of conductive hearing loss for over 50 years. The change in such quantities after stimulation of the acoustic reflex also has been used in ...
متن کاملWideband acoustic immittance: Concepts and clinical utility
Measurements of middle ear (ME) acoustic power flow and related measures (e.g., reflectance, absorbance, impedance, resistance, and reactance) have several important advantages over other measures of acoustic impedance, such as the clinical “gold standard” measure, tympanometry. In addition to its wide bandwidth and ease of use, the absorbance curve, on a dB scale, has a shape that is similar t...
متن کاملQuantifying air-conducted acoustic radiation from the bone-conduction vibrator.
Sound pressure levels in the external auditory canals of 50 subjects were measured at 2000 and 4000 Hz with a bone-conduction vibrator on the forehead, the mastoid ipsilateral to the probe microphone, and the mastoid contralateral to the probe microphone. A plug was placed in the external auditory canal to minimize sound pressure levels in the external auditory canal produced by the osseotympan...
متن کاملEar and Hearing Effects of Negative Middle Ear Pressure on Wideband Acoustic Immittance in Normal- Hearing Adults
Abstract: Objectives: Wideband acoustic immittance (WAI) measurements are capable of evaluating middle ear performance over a wide range of frequencies relevant to human hearing. It is known that static pressure in the middle ear cavity affects sound transmission to the cochlea, but only a few data sets exist to quantify the relationship between middle ear transmission and pressure level. The p...
متن کامل