A Randomized Cadaver Study Comparing First-Attempt Success Between Tibial and Humeral Intraosseous Insertions Using NIO Device by Paramedics

نویسندگان

  • Lukasz Szarpak
  • Zenon Truszewski
  • Jacek Smereka
  • Paweł Krajewski
  • Marcin Fudalej
  • Piotr Adamczyk
  • Lukasz Czyzewski
چکیده

UNLABELLED Medical personnel may encounter difficulties in obtaining intravenous (IV) access during cardiac arrest. The 2015 American Heart Association guidelines and the 2015 European Resuscitation Council guidelines for cardiopulmonary resuscitation (CPR) suggest that rescuers establish intraosseous (IO) access if an IV line is not easily obtainable.The aim of the study was to compare the success rates of the IO proximal tibia and proximal humerus head access performed by paramedics using the New Intraosseous access device (NIO; Persys Medical, Houston, TX, USA) in an adult cadaver model during simulated CPR.In an interventional, randomized, crossover, single-center cadaver study, a semi-automatic spring-load driven NIO access device was investigated. In total, 84 paramedics with less than 5-year experience in Emergency Medical Service participated in the study. The trial was performed on 42 adult cadavers. In each cadaver, 2 IO accesses to the humerus head, and 2 IO accesses to the proximal tibia were obtained.The success rate of the first IO attempt was 89.3% (75/84) for tibial access, and 73.8% (62/84) for humeral access (P = 0.017). The procedure times were significantly faster for tibial access [16.8 (interquartile range, IQR, 15.1-19.9] s] than humeral access [26.7 (IQR, 22.1-30.9) s] (P < 0.001).Tibial IO access is easier and faster to put in place than humeral IO access. Humeral IO access can be an alternative method to tibial IO access. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT02700867.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraosseous versus intravenous vascular access during out-of-hospital cardiac arrest: a randomized controlled trial.

STUDY OBJECTIVE Intraosseous needle insertion during out-of-hospital cardiac arrest is rapidly replacing peripheral intravenous routes in the out-of-hospital setting. However, there are few data directly comparing the effectiveness of intraosseous needle insertions with peripheral intravenous insertions during out-of-hospital cardiac arrest. The objective of this study is to determine whether t...

متن کامل

An observational, prospective study comparing tibial and humeral intraosseous access using the EZ-IO.

INTRODUCTION Intraosseous (IO) access is an alternative to conventional intravenous access. The proximal tibia and proximal humerus have been proposed as suitable sites for IO access. METHODS A nonrandomized, prospective, observational study comparing flow rates and insertion success with tibial and humeral IO access in adults using the EZ-IO-powered drill device was conducted. The tibia was ...

متن کامل

Intraosseous vascular access in adults using the EZ-IO in an emergency department

BACKGROUND Intraosseous (IO) access is an alternative to conventional intravenous access. AIMS We evaluate the use of the EZ-IO as an alternative vascular access for patients in the emergency department. METHODS A non-randomized, prospective, observational study was performed in adults using the EZ-IO powered drill device. RESULTS Twenty-four patients were recruited. There were 35 intraos...

متن کامل

Paramedics successfully perform humeral EZ-IO intraosseous access in adult out-of-hospital cardiac arrest patients.

OBJECTIVE Studies on humeral placement of the EZ-IO (Vidacare, Shavano Park, TX, USA) have shown mixed results. We performed a study to determine the first-attempt success rate at humeral placement of the EZ-IO by paramedics among prehospital adult cardiac arrest patients. METHODS A retrospective cohort analysis of data prospectively collected over a 9-month period. Data are a subset extracte...

متن کامل

Comparison of Two Intraosseous Devices: The NIO Versus the EZ-IO by Novice Users-A Randomized Cross Over Trial.

BACKGROUND During resuscitation in the field, intraosseous (IO) access may be achieved using a variety of available devices, often attempted by inexperienced users. AIM We sought to examine the success rate and ease-of-use ratings of an IO device, the NIO® (New Intraosseous Persys Medical, Houston, TX, USA) in comparison to the Arrow® EZ-IO® (Teleflex Medical Research Triangle Park, NC, USA) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016